232
(b) Immunity requirements
*1
The Ethernet adapter module is an open-type device (a device designed to be housed inside other equipment) and must
be installed inside a conductive control panel. The corresponding tests were conducted with the Ethernet adapter
module installed inside a control panel.
*2
The accuracy of an analog-digital converter module may temporary vary within
10%.
Specification
Test item
Test details
Standard value
EN61131-2: 2007
EN61000-4-2
Electrostatic discharge
immunity
Immunity test in which
electrostatic is applied to
the cabinet of the
equipment.
• 8kV Air discharge
• 4kV Contact discharge
EN61000-4-3
Radiated, radio-frequency,
electromagnetic field immunity
Immunity test in which
electric fields are irradiated
to the product.
80% AM modulation @1kHz
• 80M-1000MHz: 10V/m
• 1.4G-2.0GHz: 3V/m
• 2.0G-2.7GHz: 1V/m
EN61000-4-4
Electrical fast transient/burst
immunity
Immunity test in which burst
noise is applied to the
power line and signal line.
• AC/DC main power, I/O power, AC I/O
(unshielded): 2kV
• DC I/O, analog, communication: 1kV
EN61000-4-5
Surge immunity
Immunity test in which
lightning surge is applied to
the power line and signal
line.
• AC power line, AC I/O power,AC I/O
(unshielded): 2kV CM, 1kV DM
• DC power line, DC I/O power: 0.5kV CM, DM
• DC I/O, AC I/O (shielded), analog
communication: 1kV CM
EN61000-4-6
Immunity to conducted
disturbances, induced by radio-
frequency fields
Immunity test in which high
frequency noise is applied
to the power line and signal
line
0.15M-80MHz, 80% AM modulation
@1kHz, 10Vrms
EN61000-4-8
Power-frequency magnetic field
immunity
Immunity test in which the
product is installed in
inductive magnetic field
50Hz/60Hz, 30A/m
EN61000-4-11
Voltage dips and interruption
immunity
Immunity test in which
power supply voltage is
momentarily interrupted
• Apply at 0%, 0.5 cycles and zero-cross point
• 0%, 250/300 cycles (50/60Hz)
• 40%, 10/12 cycles (50/60Hz)
• 70%, 25/30 cycles (50/60Hz)
Содержание NZ2GF-ETB
Страница 1: ...CC Link IE Field Network Ethernet Adapter Module User s Manual NZ2GF ETB ...
Страница 2: ......
Страница 49: ...47 CHAPTER 4 PROCEDURE BEFORE THE OPERATION 4 4 1 Start Up Procedure Memo ...
Страница 82: ...80 10 The following dialog box is displayed 11 Set the switch on the Ethernet adapter module to RUN Click ...
Страница 198: ...196 a Detail Setting ...
Страница 246: ...244 Memo ...
Страница 253: ......