197
CHAPTER 10 CONFIGURATION TOOL
10
10.
3 Par
a
met
e
rs
The following table lists the setting items on the dialog box.
*1
Unpassive: Allows connections with no restrictions on the IP address and port number of the destination.
*2
Fullpassive: Allows connections only when the IP address and port number of the destination meet the specified ones. If
an external device with any other IP address and/or port number tries to open a connection, the line will be automatically
disconnected.
However, if the destination port number and destination IP address are set to default values, connections are allowed
with no restrictions on the IP address and port number of the destination.
*3
No setting is required when "Unpassive" is set for "TCP Connection".
Item
Description
Setting range
Name Setting
Equipment
Name
Enter an equipment name.
8 characters or less
(Default: Eqpt-1-Connection No.)
Comment
Enter a comment.
32 characters or less
(Default: Connection-Connection No.)
TCP Connection
Select a TCP connection type.
Set this item only when "TCP" is selected for "Protocol" in the
"Ethernet Port Connection Setting" window.
There are two TCP connection types: Unpassive
and
Fullpassive
.
Unpassive/Fullpassive
(Default: Unpassive)
Destination Port No.
Input
Format
Select a format used for entering the port number of the
external communication-target device.
DEC/HEX
(Default: HEX)
Port No.
Enter the port number of the external device with which
communications are made.
• Decimal input
1 to 65535 (Default: 65535)
• Hexadecimal input
1
H
to FFFF
H
(Default: FFFF
H
)
Destination IP Address
Input
Format
Select a format used for entering the IP address of the external
communication-target device.
DEC/HEX
(Default: DEC)
IP Address
Enter the IP address of the external device with which
communications are made.
• Decimal input
0.0.0.1 to 255.255.255.255
(Default: 255.255.255.255)
• Hexadecimal input
0.0.0.01 to FF.FF.FF.FF
(Default: FF.FF.FF.FF)
Содержание NZ2GF-ETB
Страница 1: ...CC Link IE Field Network Ethernet Adapter Module User s Manual NZ2GF ETB ...
Страница 2: ......
Страница 49: ...47 CHAPTER 4 PROCEDURE BEFORE THE OPERATION 4 4 1 Start Up Procedure Memo ...
Страница 82: ...80 10 The following dialog box is displayed 11 Set the switch on the Ethernet adapter module to RUN Click ...
Страница 198: ...196 a Detail Setting ...
Страница 246: ...244 Memo ...
Страница 253: ......