Function 6
6-1
6.
Function
6.1
Function list
The functions of the GOT are divided into 6 modes. The operator can use each function by
selecting the corresponding mode.
Mode
Function
Outline of function
Reference
sections
Screen
mode
Character
display
• Alphanumerics are displayed.
9
18
20
Drawing
• Straight lines, circles and rectangles are displayed.
Lamp display
• The color of a specified area on the screen is inverted in
accordance with the ON/OFF status of the bit devices in
the PLC.
Graphic display
• Set values and current values of the word devices in the
PLC can be displayed in the form of bar graph, line graph
or panel meter.
Data display
• Set values and current values of the word devices in the
PLC can be displayed in the form of numeric.
Data change
function
• Current values and set values of the word devices are the
PLC can be changed.
Switch function
• The ON/OFF status of bit devices in the PLC are
controlled.
• Controll can be in the format of momentary, alternate or
set/reset.
Screen
changeover
• The display screen can be changed over. The PLC or
touch key can be used to change over the display screen.
Data batch
transfer
• Data saved in the GOT can be transferred to the PLC.
Security
function
• Screens are displayed only when the proper password is
entered. (This function is available also in the system
screens.)
7
HPP
mode
Program (list)
• Programs can be read/written/monitored in instruction list
program format.
10
Parameter
• Parameters for the program capacity, memory latch range,
etc. can be read/written.
BFM monitor
• Buffer memories (BFM) in special blocks for the FX
2N
/
FX
2NC
Series can be monitored, and their set values
changed.
Device monitor
1)
• The ON/OFF status of bit devices as well as current values
and set values of word devices can be monitored using
device Nos. and comment expression.
Current value/
set value
change
2)
• Current values and set values of word devices can be
changed using device Nos. and comment expression.
Graphic Operation Terminal GOT-F900
Содержание F930GOT-BWD
Страница 1: ...OPERATION MANUAL GOT F900 ...
Страница 4: ...Graphic Operation Terminal GOT F900 ii ...
Страница 6: ...Graphic Operation Terminal GOT F900 iv ...
Страница 14: ...Graphic Operation Terminal GOT F900 Contents xii ...
Страница 16: ...Graphic Operation Terminal GOT F900 Manual configuration and various data 2 MEMO ...
Страница 30: ...Graphic Operation Terminal GOT F900 Introduction 1 1 14 MEMO ...
Страница 34: ...Graphic Operation Terminal GOT F900 Outside dimensions 3 3 2 MEMO ...
Страница 38: ...Graphic Operation Terminal GOT F900 Part names 4 4 4 MEMO ...
Страница 42: ...Graphic Operation Terminal GOT F900 Installation 5 5 4 MEMO ...
Страница 90: ...Graphic Operation Terminal GOT F900 Creation of Display Screens 8 8 32 MEMO ...
Страница 154: ...Graphic Operation Terminal GOT F900 Alarm Mode 12 12 14 MEMO ...
Страница 164: ...Graphic Operation Terminal GOT F900 Test Mode 13 13 10 MEMO ...
Страница 174: ...Graphic Operation Terminal GOT F900 Connection to Bar Code Reader 15 15 2 MEMO ...
Страница 180: ...Graphic Operation Terminal GOT F900 Screen Hard Copy Function 16 16 6 MEMO ...
Страница 274: ...Graphic Operation Terminal GOT F900 Changeover of Display Screen FX PCS DU WIN E 19 19 18 MEMO ...
Страница 320: ...Graphic Operation Terminal GOT F900 Creation of Display Screen GT Designer 20 20 46 MEMO ...
Страница 341: ......