Graphic Operation Terminal GOT-F900
Sampling Mode 11
11-6
11.2.2
START COND.
Set the timing at which sampling is started. (Even if the sampling condition (trigger or constant
cycle) is satisfied, sampling is not performed if the start condition is not satisfied.)
•
Sampling start by trigger
When X, Y, M, S, T or C becomes ON (OFF
à
ON)
or OFF (ON
à
OFF)
,
sampling is started. (D, Z and V cannot be specified.)
•
Sampling start by time
The time can be set within the range of 1 second to 31 days, 23 hours, 59 minutes and 59
seconds. When the specified time has come, sampling is started.
u
u
u
u
Basic operation
TIME
SET
START COND.
Select "START
COND.".
SET CONDITION
screen is displayed.
DEVICE
Select "DEVICE".
Screen 1 is
displayed.
Select "TIME".
Screen 2 is
displayed.
1) Sampling start
by trigger
2) Sampling start by time
1)
2)
Display the
device input
keyboard.
Device symbol
Device No.
ENT
OFF -> ON
Execute
the input.
Change over
"OFF -> ON" and
"ON -> OFF".
Select a bit device among X, Y, M, S, T and C.
SET
Display the
ten-key pad.
0 to 9
Set date, hour, minute
and second.Set date,
hour, minute and second.
ENT
They are changed over alternately.
[ SET CONDITION ]
END
START COND.
M 0
DEVICE
SET
OFF->ON
Screen 1
[ SET CONDITION ]
END
START COND.
0d 0h 0m 0s
TIME
SET
Screen 2
Содержание F930GOT-BWD
Страница 1: ...OPERATION MANUAL GOT F900 ...
Страница 4: ...Graphic Operation Terminal GOT F900 ii ...
Страница 6: ...Graphic Operation Terminal GOT F900 iv ...
Страница 14: ...Graphic Operation Terminal GOT F900 Contents xii ...
Страница 16: ...Graphic Operation Terminal GOT F900 Manual configuration and various data 2 MEMO ...
Страница 30: ...Graphic Operation Terminal GOT F900 Introduction 1 1 14 MEMO ...
Страница 34: ...Graphic Operation Terminal GOT F900 Outside dimensions 3 3 2 MEMO ...
Страница 38: ...Graphic Operation Terminal GOT F900 Part names 4 4 4 MEMO ...
Страница 42: ...Graphic Operation Terminal GOT F900 Installation 5 5 4 MEMO ...
Страница 90: ...Graphic Operation Terminal GOT F900 Creation of Display Screens 8 8 32 MEMO ...
Страница 154: ...Graphic Operation Terminal GOT F900 Alarm Mode 12 12 14 MEMO ...
Страница 164: ...Graphic Operation Terminal GOT F900 Test Mode 13 13 10 MEMO ...
Страница 174: ...Graphic Operation Terminal GOT F900 Connection to Bar Code Reader 15 15 2 MEMO ...
Страница 180: ...Graphic Operation Terminal GOT F900 Screen Hard Copy Function 16 16 6 MEMO ...
Страница 274: ...Graphic Operation Terminal GOT F900 Changeover of Display Screen FX PCS DU WIN E 19 19 18 MEMO ...
Страница 320: ...Graphic Operation Terminal GOT F900 Creation of Display Screen GT Designer 20 20 46 MEMO ...
Страница 341: ......