background image

JAN 2008

REGISTERED TO ISO 9001:2000

8F, No.31, Lane 169, Kang-Ning St., Hsi-Chih Taipei Hsien, 221 Taiwan

Phone: (886) 2-2695-4214

FAX: (886) 2-2695-4213

www.gigatms.com.tw

1

Содержание GUARDSCAN GS120

Страница 1: ...JAN 2008 REGISTERED TO ISO 9001 2000 8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Hsien 221 Taiwan Phone 886 2 2695 4214 FAX 886 2 2695 4213 www gigatms com tw 1 ...

Страница 2: ...ithout notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of GIGA TMS INC Rev Number Date Notes REVISIONS 01 MAY 07 Initial Release 02 JAN 08 Add RFID Scan Time Register 2 ...

Страница 3: ...ction against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the use...

Страница 4: ...Keep battery contact surfaces and battery compartment contacts clean by rubbing them with a clean pencil eraser or a rough cloth each time you replace batteries 6 Keep batteries away from children If swallowed contact a physician at once 7 Don t recharge a battery unless it is specifically marked rechargeable Attempts to recharge an alkaline battery may cause an imbalance within the cell leading t...

Страница 5: ...rd Package Main unit GS120 RS232 Cable WAS T0017 LR03 AAA ALKALINE 1 5V Battery BAT T0010 Chain Sling TM09F1001 USB Cable for GS120U series WAS 1571 CD ROM RS232 Cable for GS120 series WAS T0017 Information 5 ...

Страница 6: ...read bad memory or incorrectly encoded data and so on the device will turn on the ERROR indicator RFID Card Scan Area Scan the RFID card to reader Technical and Operational Description Battery Box Put the battery in box and hold battery Connector For connection to host computer and external Power Operate Keypad Turn the GS120 on off power and Operate Operation LED Indicator LCD Main Screen Chain S...

Страница 7: ...ewing Database Main Menu Item When Operating Menu Sub Menu Item When Operating Submenu 1 Corresponding Key Power Exit Back Cancel No Key Function 2 Corresponding Key 3 Corresponding Key 4 Corresponding Key Up Up scroll Decrease Scan Key Function Down Down scroll Increase Event Key Function Menu Enter Save Next Yes Key Function Technical And Operational Description LCD Display Display Date Week Tim...

Страница 8: ...t ON Reset Default BackLight 15 seconds Auto Power Off 30 seconds Power Mode Switch Mode Sound ON 3 1 Status 3 2 View Display Memory Status Used Space Unused Space Total Space Display all records in memory 4 1 Date Format 4 2 Set Date Time Set Date Format Select Year Month Date Date Month Year Month Date Year Default Month Date Year Set Date Year Month Date Set Time Week Hour Minute Second 5 1 Pro...

Страница 9: ...lready is full After scan card LCD Display message Check RTC Check FLASH Decode Error No Record Record not empty ISP MODE FLASH Full Counterplot Set Date and Time Contact Agent Scan Card again or Change Card Scan Card Download Records and Erase Records Update New Firmware Download Records and Erase Records Status Power On Ready Read OK Read Error Green LED Take turns blink 2 times Off Blink 1 time...

Страница 10: ...urns to blink this means the RTC is malfunctioning and you must do the RTC time setting before you use the unit When the device is powered by battery it would have Low Battery Detection function When the battery goes low the LCD would display and you must change battery immediately otherwise the unit would shut down any time without pre warning 5 Scan RFID Card 6 Operating for Calendar 7 Memory Fu...

Страница 11: ... Take the cover away 3 Take the battery away 4 Take new battery 5 Put new battery in 6 Fix the battery cover Note 1 Read the instructions on your device before replace new battery 2 GS120 can use Single cell alkaline nickel cadmium NiCd or nickel metal hydride NiMH Battery 11 ...

Страница 12: ...2 5 External power DC 5V GS120 DSUB 9P POWER JACK No use Note 1 When GS120 is connected disconnected with an external power adapter it would be turned On Off automatically 2 When GS120 is not connected with an external power adaptor the corresponding key for power on GS120 needs to be pressed all the time during the communications with the PC 12 ...

Страница 13: ...WAS 1571 USB interface cable 1 1 Connections Note 1 When GS120 is connected disconnected with USB port it would be turned On Off automatically USB 4P FEMALE PIN 1 3 2 4 FUNCTION VCC D D GND MINI USB 4P 1 3 2 4 FUNCTION RXD TXD VCC GND GS120 13 ...

Страница 14: ...DATA STRING TIME STX CR CARD TYPE DATE TIME DATE DATE TIME TIME SP 1 SP is the SPACE characters 20h 2 TIME is 24hrs YYYY MM DD HH MM SS SP STX CARD TYPE CARD ID CR A SP CARD TYPE 10 CARD ID CARD TYPE EM 125K 5 14 ...

Страница 15: ...T V1 2 Memory Size for Storing Data RTC CLOCK CMOS Serial Flash Memory 512K bytes Up to 8192 records 32 Bytes Record Real Time Clock RTC module and back up capacitor USB Interface Full compliance with the USB Specification V 1 1 The device uses a Virtual Serial Port Driver making it appear to have the software like a standard RS232 Serial Port USBVer 1 1 LCD Single Cell LR03 AAA LCD Display LCD ty...

Страница 16: ...3 NACK Handshaking STX CMD CONTENTS CR PACKET STX CMD CONTENTS CHKSUM CR 2 B Start of Text 02 STX REPLY CONTENTS CR ITEM Dec Control Key Function Hex 13 M Carriage Return 0d ASCII ASCII Command Code ASCII ASCII ASCII Contents Data ASCII ASCII ASCII Check Sum ASCII REPLY 78 65 N A Negative Acknowledge 4e 41 16 ...

Страница 17: ...ent Mode Set Password Logout Erase All Record J I Get Machine ID Set Machine ID D I Access Denied Invalid Command or Data F E Command Execution Failed Database is Empty GS120 Terminal has an extensive list of Commands that allow manipulating its internal database setting functional parameters and getting data on its current status There are 2 levels of access to the GS120 User and Supervisor Super...

Страница 18: ...0d EXAMPLE PASSWORD PASSWORD 4 Characters for Login 0000 Initial value 0000 LOGOUT STX O CR STX A CR 02 O 0d Logout 02 A 0d EXAMPLE SET PASSWORD STX P CR STX A or D or I CR PASSWORD PASSWORD New four characters password 02 D 0d Login password command is not executed 02 I 0d Invalid password Access Security Commands 18 ...

Страница 19: ...0800h READ RECORD BY NUMBER STX G CR STX A CR 02 G 0d DATE 20070530 TIME 10 39 23 DATA ABCDEF1234 02 A 0d EXAMPLE DATA 20h DATA 20h Record Data ABCDEF1234 DATE TIME DATA TIME DATE TIME 20070530 103923 20 STX E or D or F CR 02 E 0d Database is empty 02 P 0d Set new password 1234 02 A 0d EXAMPLE 1234 02 D 0d Set new password is not executed Invalid password 02 I 0d 19 ...

Страница 20: ... is not executed RECOVERY ALL DATABASE READOUT TRANSACTION STX M CR STX A or I CR 02 M 0d 02 A 0d EXAMPLE Database is recovery 02 I 0d Invalid command 02 E 0d Erase all records 02 A 0d EXAMPLE 02 D 0d Erase command is not executed Communication Protocol ERASE ALL RECORD STX E CR STX A or D CR Erase Duration 60 seconds 20 ...

Страница 21: ...serial number ROM T0842 Firmware version 1 00 Modify times 1 02 A 0d V1 00R1 EXAMPLE ROM T0842 SET DATE AND TIME STX S CR STX A or I or D CR 02 S 0d Set Date 2000 5 6 Set Time 12 30 00 02 A 0d YYYYMMDDhhmmss 20000506123000 EXAMPLE YYYY MM DD hh mm ss Year 2000 20xx Month 01 12 Date 01 31 Hour 00 23 Minute 00 59 Second 00 59 Invalid Date Time 02 I 0d Set Date Time is not executed 02 D 0d 21 ...

Страница 22: ...LE YYYYMMDDhhmmss 20000506123000 Get Date Time is not set or invalid 02 F 0d SET MACHINE ID STX J CR STX A or I or D CR 02 J 0d Set Machine ID 00 02 A 0d EXAMPLE 00 255 00 Invalid command or data 02 I 0d 02 D 0d Set Machine ID is not executed Get Date 2000 5 6 Get Time 12 30 00 22 ...

Страница 23: ...ARE MANAGEMENT MODE STX X CR STX A CR 02 X 0d Enter firmware management mode 02 A 0d EXAMPLE 02 I 0d Get Machine ID 00 02 A 0d EXAMPLE 00 Get Identification is not set or otherwise invalid 02 F 0d GET MACHINE STX I CR STX A CR 00 255 23 ...

Страница 24: ...econd 00h Off FFh On 00h mm dd yyyy FFh yyyy mm dd other dd mm yyyy ID Number 16 Characters Password 30 1FBh 1FC 1FFh 4 Characters GET REGISTER STX B CR STX A CR REGISTER REGSTER PARAM CHKSUM PARAM Register Address 2 Bytes Width 00h FFh Set Parameters of Register SET REGISTER STX C CR STX A CR REGISTER REGISTER PARAM CHKSUM PARAM Register Address 2 Bytes Width 00h FFh Set Parameters of Register CH...