62
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Operation examples (continued)
1
<MOTION DETECTION SETTINGS>
>>SELECTION CAMERA NUMBER
DETECTION MASK SETTING
SENSITIVITY HIGH••<<<LOW
MOTION THRESHOLD 5
TEST MODE
MD LOCK OUT TIME OFF
4) <TIMER PROGRAM SETTINGS> screen setting (
see pages 44 to 46)
• SELECTED PATTERN: “P3”
• ALARM REC DURATION: “5M”
<TIMER PROGRAM SETTINGS>
>>SELECTED PATTERN P3-SET
HOLIDAY SETTING
REC MODE A
REC MODE B
REC MODE C
REC MODE D
ALARM REC DURATION 5M
5) <ALARM SETTING C> screen setting (
see page
46)
• All the cameras (“
1
” to “
4
”):
• TRIGGER: “MD/EXT”
• EMR: Set all the cameras (“
1
” to “
4
”).
<ALARM SETTING C>
ALARM RECORD CAMERA TRIGGER
>>1 --- MD/EXT
2 - -- MD/EXT
3 -- - MD/EXT
4 --- MD/EXT
EMR
ALARM TYPE ALARM CH
CLEAR:BACK
4
1
2
3
4
1 2 3
6) <RECORD SETTING C> screen setting (
see page
46)
• All the cameras (“
1
” to “
4
”):
• PPS, GRADE, A-PPS, A-GRADE: Set the desired
interval and picture quality for each camera.
• ALARM TYPE: “ALARM CH”
• PRE ALARM REC: Set the desired pre-alarm recording time.
4
1
2
3
<RECORD SETTING C>
NO PPS GRADE A-PPS A-GRADE
>> 3.125P STD 3.125P HIGH
3.125P STD 3.125P HIGH
3.125P STD 3.125P HIGH
3.125P STD 3.125P HIGH
ALARM TYPE ALARM CH
PRE ALARM REC MEDIUM
CLEAR:BACK
<ESTD REC> D H M
7) <ALARM SETTING D> screen setting (
see page
46)
• Camera numbers “
1
” and “
3
” only:
• TRIGGER: “MD/EXT”
<ALARM SETTING D>
ALARM RECORD CAMERA TRIGGER
>>1 --- MD/EXT
2 - -- EXT
3 -- - MD/EXT
4 --- EXT
EMR
ALARM TYPE ALARM CH
CLEAR:BACK
4
1
2
3
4
1 2 3
8) <RECORD SETTING D> screen setting (
see page
46)
• Camera numbers “
1
” and “
3
” only:
• PPS, GRADE, A-PPS, A-GRADE: Set the desired
interval and picture quality for each camera.
• Other camera:
• PPS: “- - - - - -”
• ALARM TYPE: “ALARM CH”
• PRE ALARM REC: Set the desired pre-alarm recording
time.
4
1
2
3
<RECORD SETTING D>
NO PPS GRADE A-PPS A-GRADE
>> 6.25P SUPER ------ STD
------ STD ------ STD
6.25P SUPER ------ STD
------ STD ------ STD
ALARM TYPE ALARM CH
PRE ALARM REC MEDIUM
CLEAR:BACK
<ESTD REC> D H M
9) <TIMER PROGRAM> screen setting (
see page 44)
• PROGRAM NO.1 : “SPL,” “08:00,” “15:00,” “C,” “ON.”
• PROGRAM NO.2 : “SPL,” “15:00,” “08:00,” “D,” “ON.”
• PROGRAM NO.3 : “SAT,” “08:00,” “08:00,” “D,” “ON.”
• PROGRAM NO.4 : “SUN,” “08:00,” “08:00,” “D,” “ON.”
• SPL: “MON - FRI”
<TIMER PROGRAM> P3
DW START END MODE MD
>>1 SPL 08:00 15:00 C ON
2 SPL 15:00•08:00 D ON
3 SAT 08:00•08:00 D ON
4 SUN 08:00•08:00 D ON
5 --- --:-- --:-- ---- ---
6 --- --:-- --:-- ---- ---
7 --- --:-- --:-- ---- ---
8 --- --:-- --:-- ---- ---
SPL MON-FRI
When completed with all the settings above and after
clearing the menu screen, press both the TIMER ON/
OFF buttons. The unit switches to the timer
programming mode.