83
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Warnings and CALL OUT output
ENGLISH
Warnings and CALL OUT output
■
Warnings and their appropriate countermeasures
#1 Options in the CALL OUT output column:
• Selectable :
selects to output CALL OUT signal or not on the menu screen.
• Fixed
:
outputs CALL OUT signal from the CALL OUT terminal regardless of the menu setting.
• None
:
does not output CALL OUT signal, but displays a warning on the screen.
CALL OUT signal output can be stopped by pressing the WARNING RESET button.
Warning Display
CALL OUT
output
#1
page
Canceling
the warning
Code
Status
Countermeasure
REC/FULL
REC/SUB FULL
REC/REM
NO SIGNAL
(The warning indicates
the number of the
non-functioning
camera. )
IMAGE MODIFIED
SYSTEM ERROR
REC/
SYSTEM ERROR
PLAY/
SYSTEM ERROR
REC/RW
MIRROR
<DEVICE ERROR>
TEMP
FAN
(NONE)
WNG1100
WNG1101
WNG1200
(MAIN)
WNG1201
(SUB)
WNG54 #3
WNG5500
WNG5100
WNG14 #2
WNG24 #2
WNG13 #2
WNG6100
WNG6200
WNG5200
WNG5300
WNG5101
47
14-17
14-17
12
37
25, 26
41-43
47, 48
-
-
56, 57
71
56, 57
14-17
-
-
-
Selectable
Selectable
Fixed
Fixed when
setting is
“ON”
Fixed
None
Fixed
Fixed
None
Fixed
• MAIN HDD recordable
capacity is full.
• SUB HDD recordable
capacity is full.
• The remaining HDD
capacity has reached the
value set in HDD REMAIN.
• Video signal was lost for
more than 5 seconds
during recording.
• Video data that has been
altered was played back.
• System error has
occurred.
• Error has occurred during
writing of data to HDD.
• One HDD could not be
detected during mirroring.
• Unable to recognize
HDD.
• HDD or HDD tray is
connected or attached
incorrectly.
• Issued when in a high
temperature environment
within the tolerance level.
• The fan stops.
• Reboots by watchdog
operation.
Press and hold
the WARNING
RESET button.
Press and hold
the WARNING
RESET button.
Stop recording.
Output video
signals.
Press and hold
the WARNING
RESET button.
Press and hold
the WARNING
RESET button.
Press and hold
the WARNING
RESET button.
Press and hold
the WARNING
RESET button.
Press and hold
the WARNING
RESET button.
Turn off the
power.
Press and hold
the WARNING
RESET button.
Lower
the temperature.
Press and hold
the WARNING
RESET button.
Rotate the fan.
• When the warning is
cancelled, the unit starts
over-writing the oldest data
remaining in the hard disk
drive.
• Replace with new HDD.
• Replace with new HDD.
• Check whether the unit
and camera are properly
connected, and that electri
-city is on.
• Check whether the video
signal is being properly
output.
• Check that whether there
is a camera set for operation
with no video signal input.
• Reboot.
• Check the HDD.
• Check the HDD.
• Reboot.
• Reboot.
• Check that the HDD or
HDD tray is connected or
attached correctly.
• Turn off the power and
change the installation
condition.
• Turn off the power and
stop usage.
#2 : (The following numbers are in )
00 : A (MASTER) 01 : B (SLAVE)
#3 : (The following numbers are in )
01 : CAMERA IN 1 02 : CAMERA IN 2
03 : CAMERA IN 3 04 : CAMERA IN 4