5-10
Message
Cause
Solution
Any parameter outside the range of
acceptable numeric values was
received.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The received data does not follow
the command system set by the
machine.
Transmit data that is compatible with the
command system supported by this
machine.
An error occurred in communication
between the host computer and the
interface board for USB2.0 connec-
tion.(Full-Speed mode connection)
Check that the host PC supports the
USB2.0 interface.
(Communication can be resumed without
changing any setting. However, it is rec-
ommend to use the connection in High-
Speed mode.)
An error occurred in communication
between the host computer and the
interface board for USB2.0 connec-
tion.
Check that the cable is securely con-
nected to the host computer and interface
board.
Also, check to see if any error has
occurred on the host computer.
An error occurred in communication
between the host computer and the
interface board for USB2.0 connec-
tion.
An error occurred in communication
between the host computer and the
interface board for USB2.0 connec-
tion.
An error occurred in communication
between the host computer and the
machine for USB2.0 connection.
Improper operation was conducted
on the operation panel.
Perform correct operations.
It is being tried to change settings
for functions though there remains
received data that has not yet been
printed.
Print all the received data or execute the
data clear function. Then, change settings.
An excessive load was applied to
the X motor.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
An excessive load was applied to
the Y motor.
An error due to an excessive cur-
rent of the X motor was detected.
An error due to an excessive cur-
rent of the Y motor was detected.
An error occurred in the capping
control. (Improper parameter
adjustment value)
* * * * * E RROR 1 1 * * * * *
P A R AME T E R E RROR
* * * * * E RROR 1 6 * * * * *
MR L COMMA ND
* * * * * E RROR 2 5 * * * * *
F U L L - S P E E D
* * * * * E RROR 2 5 * * * * *
P A C K E T S I Z E OV E R
* * * * * E RROR 2 5 * * * * *
U S B P RO T OCO L
* * * * * E RROR 2 5 * * * * *
U S B E N V I RONME N T
* * * * * E RROR 2 5 * * * * *
U S B D A T A
* * * * * E RROR 3 0 * * * * *
C A N ‘ T OP E R A T E
* * * * * E RROR 3 4 * * * * *
D A T A R EMA I N
* * * * * E RROR 4 0 * * * * *
MO T OR A L A RM X
* * * * * E RROR 4 1 * * * * *
MO T OR A L A RM Y
* * * * * E RROR 4 2 * * * * *
X OV E R CURR E N T
* * * * * E RROR 4 3 * * * * *
Y OV E R CURR E N T
* * * * * E RROR 4 5 * * * * *
C A P P I NG : P A R AME T E R
Содержание JV33-130
Страница 1: ...MIMAKI ENGINEERING CO LTD URL http www mimaki co jp D201694 16 ...
Страница 7: ...vi ...
Страница 99: ...3 35 Machine settings 3 Convenient use Examples of Output ...
Страница 101: ...3 37 Machine settings 3 Convenient use 7 Press the key 8 Press the key several times to end ...
Страница 114: ...3 50 ...
Страница 147: ...Setting Routine operations 4 33 4 Routine Maintenance 8 Press the key several times to end ...
Страница 162: ...Replacing the cutter blade 4 48 4 Close the front cover 5 Press the key The machine returns to LOCAL mode ...
Страница 181: ...Warning labels 6 7 6 Appendix No Reorder Label 1 M901549 2 M903239 3 M903330 4 M903405 5 M904810 ...
Страница 185: ...6 11 Function Flowchart 6 Appendix To P 6 12 To P 6 18 To P 6 24 To P 6 25 To P 6 26 ...
Страница 189: ...6 15 Function Flowchart 6 Appendix OFF LEVEL 1 3 1 Wh i t e L a y P r t SE L OF F ...
Страница 201: ...D201694 16 31012012 ...
Страница 202: ...NH FW 5 3 MIMAKI ENGINEERING CO LTD 2012 ...