
TS3 User
Manual
page 64
8-3 Setting Bit Depth
The TS3 can record and save 10-bit or 8-bit data. The advantage of recording 10-bit data is that it
gives more fl
e
xibility in post-processing the imagery. The disadvantage is that it takes more
memory to record or save 10-bit data. When recording, you will get about 25% fewer files, and 25%
less
recording time.
When saving 10-bit data (to a mass storage device) in TIFF (RAW) format, the actual file type is a 16-
bit file, so it is su
b
stantially la
ger than an 8-bit mono file. The 10-bit (R
W) color image, however is
not colorized--it is a RAW Bayer image (not “colorized,” which would make it about 3x as large), so it is
about 2/3 the size of the 24-bit color file (8 bits per each of 3 olor channels).
To choose the recording bit depth:
1. Navigate to the Record Menu.
2. Select Bit Depth.
3. Select 8-low, 8-mid, 8-high, or 10-bit. If any of the 8-bit mappings are chosen, the live image will
immediately reflect th t change. If 10-bit is chosen, the displayed live image will default to 8-high.
If Bit Depth is set to 10 in the Record Menu, a bit depth selection will appear in the The Displ
a
y
Menu. The choices here are 8-low, 8-mid, and 8-high. This selects the 8-bits used for the display and
for saving to media.
8-4 Configuring the Trigger
The TS3 uses a fi
x
ed, selectable circular bu
ff
er to record into. The
session length is determined by the user (see “7-8 Storage Setup”
on page 59). This section
e
xplains how to set the trigger position
within the bu
ff
er. For an explanation on h
o
w the circular bu
ff
er
works and how to decide on the proper trigger position see
“Application No
t
e 3: Trigger Position and the Ci
r
cular Bu
ff
er” on
page 97.
To Set the
Trigger Position
in the TS3:
1. Open the Record Settings
T
ab.
2. Select either the “Use Percent” or “Use Frames” radio bu
tt
on.
The slider and edit box represent the session bu
ff
er, which is
the camera memory you will be recording into. The trigger position,
e
xpressed either in %
or
frames.
3. Set the position
b
y moving the slider or typing into the edit box or using the spinner bu
tt
ons.
Enabling the External Trigger
There are times when
y
ou wish to acti
v
ate the trigger electrically, either to sync the trigger with
other cameras or signals, or to maintain greater precision than can be expected through the
soft
w
are trigger in Fas
M
otion
1. Open the Record Settings
T
ab.
2. Click on the pull-down in the External Trigger box to expose the choices, which are: Rising, Falling,
or Disabled.
3. Choose “Rising” for rising signals or a switch opening and “Falling” for a falling signal or switch
closure.
Please refer to
“Appendix D: Power and I/O Connections” on page 82 for connection information
and warnings.
Figure 8-3:
Trigger Configuration
Содержание eosens TS3
Страница 1: ...User Manual 2013 3 110S 3000M eosens TS3 High Speed Handheld Camera...
Страница 15: ...11S 3000M page 5 Figure 1 4 TS3 Side View Door open Figure 1 5 TS3 Bottom View T3 User Manual...
Страница 98: ...TS3 User Manual 11S 3000M page 89 Appendix I Physical Measurements Figure 9 8 Physical Measurements...
Страница 105: ...TS3 User Manual Figure 10 4 High Mid and Low 8 Bits of the same Image...
Страница 120: ...TS3 User Manual 11S 3000M page 111...