Installer Manual
Microvideo srl
www.microvideo.eu
10
Chapter 2 –Modules Description
LED
Off
Slow Flashing
Fast Flashing
On
Led SIGNALS
(red led)
Proper operation of the
system
Alarm
Low 220 V network
Diagnostics Alarm (Areas,
Tamper, Modules)
Led STATE
(green led)
Disarmed
At least one inserting open
area
---
At least ona alarmed area
DISPLAY
The display is composed of two lines with large characters for a very easily reading.
The first line contains informations of the date, day of the week and time set in the system,
and the second line always indicate the status of all areas of the system.
Depending on the model of Control Panel, the first few characters of the second line
represent the areas and in every position a symbol indicates the status of the
corresponding area.
SY810
12 Areas managed by the system
12 characters representing areas Status
SY800
8 Areas managed by the system
8 characters representing areas Status
AREA STATUS
Description
T
TOTAL
All The Zones associated to the area are armed
P
PARTIAL
At least one zone in the area was not armed
-
NOT CONFIGURED
The zone has NO area associated
R
REST
All areas
DIRECTIONAL KEYS
The directional keys allow you to scroll up and down menu appear in the display
The arrow keys are displayed on the keyboard macro .
If a valid code is entered, using the arrow keys you can scroll through the menu and
pressing ok you can access the menu / parameter selected
INTEGRATED PROXIMITY READER
The SY820 keyboard has a built-in proximity reader . Approaching the key on the left side
of the keyboard, next to the graphic indication , if the key is properly configured, it
activates the display on the 4 macro associated with the reader and the one macro
associated with the key. When you remove the key , the System runs the macro you see
on the display in that moment.
NUMERIC KEYPAD
Using the numeric keypad , you can enter the value of all the parameters and descriptions.
In addition, through the 0 button , you can select / deselect the areas of belonging in their
own menu.