Installer Manual
Microvideo srl
www.microvideo.eu
47
CHAPTER 4– Programming Control Panel
Parameter
Options
Description
Enabled
Yes
Wall Module enabled
NO
Modulo Wall disabked
Description
12 characters
Wall module Description. Description appears during configuration, either by keyboard then
by SynergyPro SW, in every log, and in SMS messages relative to Wall module
Overload
(NoConfig,Macro1...Macro 36) Macro associated to OverLoad alarm: Overload absorption alarm
Rec Error
(NoConfig,Macro1...Macro 36) Macro associated to Wall Recording alarm
No220Net
(NoConfig,Macro1...Macro 36) Macro associated to Wall Power failure alarm
LowBattery
(NoConfig,Macro1...Macro 36) Macro associated to Wall Low Battery alarm
Fog modules
Parameter
Options
Description
Enabled
Yes
Fog machine Module enabled
NO
Fog machine Module disabled
Description
12 characters
Fog machine Module Description. Description appears during configuration, either by keyboard then by
SynergyPro SW, in every log, and in SMS messages relative to Fog machine Module
Serial Num.
20 characters
Fog machine Module serial number
DelayTime of
Boiler Heating
(0...60)
Time in minutes between an Equipment of fog machine and switching of resistors of Heat Boiler.
Shot Time
(1...60)
Time in seconds of duration of fog machine Shot on Alarm
Shot Time Delay
(0...30)
Time in seconds of delay of fog machine Shot on Alarm
Enable Fog Hold
Function
Yes
Fog Holding Function Enabled
NO
Fog Holding Function Disabled
Fog Hold Rest
(5...15)
Pause time in minutes, holding fog cycle, before next shot
Fog hold Shot time
1/2 Shot
The Shot, during fog hold cycle, will take half of Alarm Shot time
1/4 Shot
The Shot, during fog hold cycle, will take a quarter of Alarm Shot time
Fog Hold Cycle
(1...4)
Number of cycles (Shot-break sequences) that the fog machine will run to complete the function Hold Fog
Pause time between 2
shots
(0...180)
Time in minutes of Fog machine Standby after an alarm shot. During this time the fog machine won’t make any
alarm shot.
Cleaning time
(0...60)
Time in seconds of pumps functioning during cleaning cycle
Max temperature
(300...450)
Max temperature (°C) of heat boiler during fog machine arming
Min temperature
(300...450)
Min temperature (°C) of heat boiler during fog machine arming
Number of resistors
(2...4)
Number of resistors in fog module
Number of pumps
(1...2)
Number of pumps in fog module
Radio Receivers
Parameter
Options
Description
Enabled
Yes
Radio receiver enabled
NO
Radio receiver disabled
Description
12 characters
Description of Radio Receiver. Description appears during configuration, either by keyboard then by
SynergyPro SW, in every log, and in SMS messages relative to Radio Receiver Module
OK
Install Menu
13)Fog machine
Fog Machine
Fog machine 1
OK
Fog machine 1
Enabled
OK
Install Menu
14) Radio Receiv.
Radio Receiv.
Receiver 1
OK
Receiver 1
enabled