Installer Manual
Microvideo srl
www.microvideo.eu
53
CHAPTER 4– Programming Control Panel
Segn.Credito
YES
Reporting via SMS minimum credit active
NO
Reporting via SMS minimum credit NOT active
NOTE the message is sent to the first number in the contacts
VerFW
Only Read
Firmware Version of SIM900 Module
StrRqstCredit
18 characters
String to request residual credit to the Operator, NOTE: If this field is empty, the system asksthe same residual credit with the
Default number relative to the operator's SIM card
NumOpCredit
12 characters
Number to request residual credit to the Operator, NOTE: If this field is empty, the system asksthe same residual credit with the
Default number relative to the operator's SIM card
APN
50 characters
APN string for Internet connection NOTE: If this field is empty the system will attempt to connect to internet through the Default
string on the operator's SIM card
APN Number
12 characters
APN number for Internet connection NOTE: If this field is empty the system will attempt to connect to internet through the
Default number on the operator's SIM card
GSM Operator
Only Read
Displays your service provider
GSM Signal
Only Read
Displays GSM signal in real time
Residual Credit
Only Read
Displays my current credit on the SIM
LAN
Parameter
Options
Description
Enabled
Yes
LAN Module enabled
NO
LAN Module disabled
IP Address
xxx.xxx.xxx.xxx
IP address of LAN Module
Netmask
xxx.xxx.xxx.xxx
Netmask of LAN Module
Gateway
xxx.xxx.xxx.xxx
Gateway of LAN Module
DNS
xxx.xxx.xxx.xxx
DNS of LAN Module
IP ServerAPP
xxx.xxx.xxx.xxx
APP Server IP address necessary to LAN module for the proper functioning of phone APPs
ServerAPP Gate
0...65000
APP Server Gate for transmission (NB let default value at 6500)
VIGILANCE
Parameter
Options
Description
Customer Code
4 digits
Contact-ID Customer Code
Protocol
Contact-ID
Protocol of communication with the vigilance
Channel
DTMF Tones
Channel of communication with the vigilance
Phone
18 digits
Vigilance Phone Number to contact
Holidays
Parameter
Options
Description
Start day
(01/01...31/12)
Initial Day of the Holidays Period, move the selection between fields "day" and "month" using the
Special "FN" key and use arrow keys to edit the value of selected field
End day
(01/01...31/12)
Final Day of the Holidays Period, move the selection between fields "day" and "month" using the
Special "FN" key and use arrow keys to edit the value of selected field. NOTE: final day must
always be next to initial one !
Timer
(NoConfig,Timer1...Timer25) timer Setting to associate with Holidays period
Start Macro
(NoConfig,Macro1...Macro36) Macro setting that will be run on initial time bands of associated Timer
End Macro
(NoConfig,Macro1...Macro36) Macro configuration that will run on final time bands of associated Timer
Install Menu
24)Transmission
OK
Transmission
LAN
OK
LAN
Enabled
OK
Install Menu
24) Transmission
Transmission
Vigilance
OK
Vigilance
Customer Code
OK
Menu Install
25)Holidays
Holidays
Holiday 1
OK
Holiday 1
Start day