Installer Manual
Microvideo srl
www.microvideo.eu
63
Appendix C –Default Reset Procedure
Appendix C –Default Reset Procedure
To reset the DB back to factory setting, follow these steps:
1. With Control Unit turned on insert the jumper J13 and check on Keyboards displays the
following message: "Warning Jump ResetDB Entered"
2. Restart the Central through power jumper J12
3. When you reboot the Control Unit with the Jumper J13 inserted the LED DL1 and DL2
are off
4. After about 5 sec. turns on the LED DL1, indicating that Installer codes and the Code 1
have been reset.
N.B. If you want to end here the steps you need to take off within 5 seconds the reset
jumper J13
5. After about 10 seconds LED DL2 turns on: this indicates that the DB was reset
everything back to factory setting and the procedure is finished
6. After about 20 seconds DL1 and DL2 LEDs back FLASHING to inform the proper
functioning of the system