Installer Manual
Microvideo srl
www.microvideo.eu
57
CHAPTER 5 – Plant Management by GSM/GPRS Module
3.
"Command not accepted!"
→
If it is not correct the description of the
area/output/macro.
4.
"Command rejected! Number not in your address book!"
→
If you are trying to
communicate with the control unit with a number not in your address book and the option
"Allow calls only from Address Book" is checked
In case is configured the confirmation setting by rings, the feedback of the dialer will be:
• 1 ring to report an accepted command
• 2 rings to report a command that does not exist
• 3 rings to report an incorrect description entered
APPENDIX A - Glossary
ALARM
Unbalance of a sensor that generates an event recognized as Intrusion
AREA
Set of one or more sensors associated for geographical proximity or logic
ARMING
DISARMING
Procedures for activation and deactivation of the Plant, and after an Arming procedure, state changes of the Areas (due to sensor alarms
that make up the area itself) generate events and then actions.
After a disarming process an alarm generated by a sensor does not generate events.
FORCED ARMAMING
Procedure to Arm the system even if, at the time the procedure of insertion, there are sensors in alarm
ZONE ACTIVATING AND
DEACTIVATING
The Central (SY800/810) ignores alarms generated by a deactive Zone . the deactivation of the area can be done manually by a user /
installer (by Keyboard, by PC or by SMS if it is present GSM SY860 module
OUTPUT ACTIVATING AND
DEACTIVATING
The Central (SY800/810) does not perform actions on the output if it is turned offthe deactivation of an Output can be done from a user /
installer manually (by Keyboard Programming, by PC or by SMS if thereis the GSM SY860 module)
ACTION
Actions are Atomic operations that the system is able to perform, such as:
• Enable Output
• Disabling Output
• Enable Keyboard Buzzer
• Sending SMS
• Voice Call
• Message Remote Vigilance
• Stop Alarms
• Stop Phone Calls
• Clear Alarm Memory
• Arm Area
• Disarm Area
CLEAR ALARM MEMORY
Each time a user interacts with a keyboard (by making a Login or consulting Log of Alarm Memory) Led Alarm / Diagnostics stops flashing
CONTROL UNIT
SY800/SY810
Main Module System: processes all data provided by modules that make up the system, is responsible for storing all the transactions
carried out and trigger the actions configured a result of Events
RFID KEY
Portable univocal apparatus associated with a user that allows you to Interact with the system through modules Keyboard SY820
Reader SY825/SY826. For each key, you can assign a description, a band Clockwise and enable a Macro (series of actions) to be
performed when the key is recognized by the system
CODE
Numerical series associated with a univocal user which allows you to Interact with the system through the Keyboard SY820 modules and
SY860 GSM dialer. For each code, you can assign a description, a time slot of enabling four Macro (series of actions) to be made when the
code is recognized by the system
INSTALLER CODE
Numerical series associated with a univocal installer that allows you to Interact with the system by keyboard module SY820. Using a valid
installer code, you can change the whole program of the system
COERCION
If the user enters the last digit of his own code increased by one unit (for example, if the code is 1234, will be entering 1235, or if the code
is 1239 entry will be 1230) will result a Special Event to which you can associate the Actions
SY860 GSM DIALER
Bi-directional module:
• Inform the user about events occurring in the system using Voice calls and / or SMS
•
• Allows interaction with the system via menus or Voice SMS commands
EVENT
The system is able to recognize a series of events (generated by the user, by the sensors, by the same system) and associate them with
the Macro, both during the activation of the event itself that its recovery. Events recognized by the system are:
• Zone Alarm
• Area Changing State
• Timer Changing State
• Inserting Code
• Key touch on
• Alarm Area
• Diagnostics Area
• Tampering
• Low Battery
• No Electricity Network
• Robbery
• Coercion
• Tamper Alarm
• GSM Failure
• Fuses Failure
• Fire
• Panic
PLANT
Set of Installed Modules, Sensors and Actuators or sirens connected to the modules that make up the system alarm.