Test Speed
Test speed is a built-in ground speed simulator that is used in
performing pre-field checks. When a typical operating speed
is entered, the MT-3405 F will respond as if you were actually
driving that speed. It allows you to simulate your spraying
application with plain water, while remaining stationary, to
make certain that all of the equipment is operating properly
and that your sprayer can actually perform the intended
application.
Test speed is cancelled by exiting CAL. Test speed will not
accumulate Distance or Area measurements.
Please refer to
Pre-Field System Checkout.
The TOTAL AREA, SUB AREA, DISTANCE and TOTAL FLOW
counters maintain a running count during operation
regardless of the position of the rotary switch. When any
of these counters reach their maximum capacity, or when
you want to start a new count, the value in the register
may be reset to zero by performing the following routine.
Counters may be reset independently of each other.
1. Place the Run/Hold switch in the HOLD position.
2. Turn the rotary switch to the counter position to be
reset.
3. Press and hold the RESET button until the display reads
zero.
4. Release the RESET button and resume normal operation.
See Illustration 19.
WIDTH
BOOM
SELECT
TEST
SPEED
ADJUST
RATE
TARGET
RATE
CIRC
MIN
FLOW
FLOW
CAL
SPEED
DISTANCE
FLOW
RATE
TOTAL AREA
APP. RATE
TOTAL FLOW
SUB AREA
ON
OFF
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
AREA
HOUR
CAL
AUTO
MAN
RESET
MT-3405
™
F
AUTOMATIC RATE CONTROLLER
MANAUTO
CALHOLD
V
1 2 3 4 5
Illustration 19
Operation
(cont)
Resetting System Counters
24
Содержание MT-3405 LR F
Страница 1: ...MT 3405 F LR AUTOMATIC RATE CONTROLLER REFERENCE MANUAL TM ...
Страница 33: ...33 Appendices ...