WIDTH
BOOM
SELECT
TEST
SPEED
ADJUST
RATE
TARGET
RATE
CIRC
MIN
FLOW
FLOW
CAL
SPEED
DISTANCE
FLOW
RATE
TOTAL AREA
APP. RATE
TOTAL FLOW
SUB AREA
ON
OFF
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
AREA
HOUR
CAL
AUTO
MAN
RESET
MT-3405
™
F
AUTOMATIC RATE CONTROLLER
MANAUTO
CALHOLD
V 1 2 3 4 5
18
Illustration 13
Calibration
Entering Calibration Values
English or Metric?
The MT-3405 F is capable of displaying in for ma tion in Amer-
i can En glish or standard Metric measurement.
• To activate the English mode, turn power OFF and place
the ro ta ry switch at “TOTAL AREA.” Hold down both the
“CAL” and “-” keys and turn power ON. See Illus tra tion
13. The con sole will display English measure ments. Once
powered up, release the two keys. To “lock-in” English
mode you must enter calibra tion. Press and hold the
CAL key until “CAL” lights on the display. The console
is now in calibration and English mode is locked-in. Exit
CAL by pressing and holding the “CAL” key until CAL
disappears from the display (approximately 3 seconds).
You must be in HOLD to enter Cal.
• To activate the Metric mode, turn power OFF and
place the ro ta ry switch at “SUB AREA.” Hold down
both the “CAL” and “-” keys and turn power ON. See
Il lus tra tion 16. The con sole will display Met ric mea sure-
ments. Once powered up, release the two keys. To
“lock-in” Metric mode you must enter cal i bra tion. Press
and hold the CAL key until “CAL” lights on the display.
The con sole is now in cal i bra tion and Metric mode is
locked-in. Exit CAL by pressing and holding the “CAL”
key until CAL disappears from the display (ap prox i mate-
ly 3 seconds). You must be in HOLD to enter Cal.
In all Calibration Operations:
1. Place the console in HOLD.
2. Press and hold the “CAL” key for three sec onds to select
the cal i bra tion mode. The con sole dis play will read
“CAL”, and the red warn ing light will turn on.
3. Turn the rotary dial to the desired “CAL” po si tion. Then
use the “+” and “-” keys to adjust the dis played val ue up
or down as needed. Adjust ALL necessary values.
See
Illustration 14.
4. Hold the “CAL” key again for three sec onds to exit
calibration. “CAL” will disappear from the dis play.
NOTE: The display will flash alternately be
tween
distance and wheel circumference when in the CIRC po si-
tion, or total flow and flowmeter cal i bra tion when in the
FLOW CAL position. When “+” or “-” is pressed, the display
will “hold” the item that was displayed when that key
was pressed. The display will resume alternations after
64 seconds of no key being depressed. Please refer to
“Entering Calibration Values,” “DISTANCE/CIRC” or “TOTAL
FLOW/FLOW CAL” for details.
NOTE: In metric, the width will have a decimal point, in
English there is no decimal point. Also, changing from
En glish to Met ric mode may change or alter any pre vi ous ly
en tered cal i bra tion values. After switch ing mea sure ment
modes, con firm that all cal i bra tion val ues are correct.
Press to enter or
exit calibration
mode.
Press to increase
or decrease
values.
Red warning light will
be lit when in CAL.
WIDTH
BOOM
SELECT
TEST
SPEED
ADJUST
RATE
TARGET
RATE
CIRC
MIN
FLOW
FLOW
CAL
SPEED
DISTANCE
FLOW
RATE
TOTAL AREA
APP. RATE
TOTAL FLOW
SUB AREA
ON
OFF
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
AREA
HOUR
CAL
AUTO
MAN
RESET
MT-3405
™
F
AUTOMATIC RATE CONTROLLER
MANAUTO
CALHOLD
V 1 2 3 4 5
Illustration 12