MFJ-1270C/1274C MANUAL COMMANDS
Page 170
PACT
IME EVERY|AFTER
n
Mode: Packet
Default: AFTER 10
Parameters:
n
0 - 250, Specifying 100 ms intervals.
EVERY Packet timeout occurs every n*100 milliseconds.
AFTER Packet timeout occurs when n*100 milliseconds elapse with no
input from the computer or terminal.
This parameter is always used in Transparent Mode, and will also be used in
Converse Mode if
CPACTIME
is
ON
. When
EVERY
is specified, input bytes
are packaged and queued for transmission every n*100 ms. When
AFTER
is
specified, bytes are packaged when input from the terminal stops for n*100 ms. In
no case will a zero length packet be produced, and the timer is not started until the
first byte is entered. A value of 0 for n is allowed, and causes packets to be gene-
rated with no wait time.
PAR
ITY
n
Mode:All
Default: 0 (none)
Parameters:
n
0 - 3,
Selecting a parity option from the table below.
This command sets the parity mode for terminal or computer data transfer
according to the following table:
n Parity
0 no
parity
1 odd
parity
2 no
parity
3 even
parity
The parity bit, if present, is automatically stripped on input and not checked in
Command Mode and Converse Mode. In Transparent Mode, all eight bits,
including parity if any, are transmitted in packets. If "no parity" is set and
AWLEN
is 7, the eighth bit will be set to 0 in Transparent Mode.
Содержание MFJ-1270C
Страница 9: ...MFJ 1270C 1274C MANUAL TABLE OF CONTENTS viii...
Страница 20: ...MFJ 1270C 1274C COMPUTER INTERFACING Page 11 20 Fig 2 3 Serial port wiring with jumpers for auxiliary signals...
Страница 241: ...MFJ 1270C 1274C MANUAL APPENDIX A RADIO HOOKUP Page 232...
Страница 258: ...MFJ 1270C 1274C MANUAL APPENDIX F JUMPERS Page 249 Fig G 1 Jumper Connector Location...
Страница 264: ...MFJ 1270C 1274C MANUAL INDEX Chapter 16 Page 29...