4 Quick-start guide
4.4.5
Safety parameters
This menu is used to parameterise the limitations and monitoring functions of the drive.
They are not functions in the sense of functional safety.
Fields that are irrelevant for the commissioning process are greyed out. Outside of the
commissioning process, the menu can be activated via
Parameters/Safety parameters
.
Figure 13: "Safety parameters" window
The
Decelerations
group can be used to define the deceleration of the drive under various
conditions.
Override
: In
Positioning
mode, the current, preset speed of movement of an active
positioning run is additionally determined by a specific factor (override). As a result, the
speed of movement stored in the position set multiplied by the override factor is taken into
consideration during the cyclic calculation. The override applies to all of the position sets
and is also used during the homing run. If it has a value of 100%, it has practically no
effect.
The override is mainly used by fieldbus systems which set this value cyclically. It is also
useful during a commissioning process. It can be used for the temporary reduction of the
speed of motion of all of the position sets without having to change this parameter
individually in the various position sets.
The override will not be saved. After a reset, the value is always 100%.
Motor overspeed protection
: If the current speed exceeds the value stated in this field,
error number 10-0 "Overspeed (motor overspeed protection)" will be issued.
Product manual BL 4000-C
Page 49 of 298
Содержание smartServo BL 4000-C Series
Страница 1: ...Important Read thoroughly before use Retain for future reference Product manual smartServo BL 4000 C ...
Страница 261: ...15 Appendix 15 2 CE conformity in accordance with the Machinery Directive Product manual BL 4000 C Page 261 of 298 ...
Страница 262: ...15 Appendix Product manual BL 4000 C Page 262 of 298 ...
Страница 263: ...15 Appendix 15 3 cULus certification Product manual BL 4000 C Page 263 of 298 ...