7 Additional settings
To avoid this situation, we recommend the following:
1. Disconnect the encoder connector.
2. Perform a reset. The encoder parameter set cannot be loaded, and the parameters
of the servo drive will not be overwritten.
3. Deactivate the option
Load parameter set from encoder EEPROM after reset
.
4. Click the
Save & Reset
button.
5. Reconnect the encoder connector.
6. Perform a reset to initialise the encoder.
Notes concerning the activation of the option:
The option can be activated when an encoder is connected as, in this case, the
parameters of the servo drive will be overwritten with the encoder parameter set from the
encoder EEPROM.
Product manual BL 4000-C