7 Additional settings
7.2
Oscilloscope
Display/Oscilloscope
The oscilloscope function of the parameterisation program can be used to display the
development of signals as well as the digital states of the servo drive. There are two
windows: the actual oscilloscope and the window for configuring the oscilloscope.
7.2.1
Oscilloscope window
Figure 71: "Oscilloscope" window
Oscilloscope buttons
The oscilloscope has several buttons to start specific activities:
Symbol
Meaning
Shifts the displayed area in the horizontal direction.
Opens the reversing generator menu.
Stops the zoom function.
Zoom function: Zooms in to the area of the oscilloscope window that
has been selected by way of the mouse.
Opens Excel and creates a spreadsheet containing the values of the
last measurement (Excel must be installed on the PC).
Prints the oscilloscope window.
Product manual BL 4000-C
Page 120 of 298