422
Chapter 14: Software installation, upgrade, and update procedures
553-3202-210 Standard October 1998
Procedure 5: Load the operating system tape on an Application Module
with an MVME147 card (continued)
Figure 158
Disk drive selection list
The MVME147 CPU Processor/SCSI Controller may be used to install
the BOS product on the following disk drive types.
The first column is the selection number, the second is the disk type
name (see the disk types associated with the ddefs(1M) utility), and
the third briefly describes the specific disk drive type:
1 m147cdcIV Seagate/CDC WREN IV 300Mb Disk (94171/MVME875)
2 m147cdcIII Seagate/CDC WREN III 150Mb Disk (94161/MVME874)
3 m147sea80 Seagate ST-296N 80Mb Disk (ST296N/M MVME873)
4 m147cdcV Seagate/CDC WREN V 600Mb Disk (94181/MVME876)
5 m147cdcVII Seagate/CDC WREN VII 1.2 GB Disk (94601/MVME877)
6 m147swift126 Seagate/CDC Swift 104 MB Disk (94351-126/MVME863)
7 m147swift201 Seagate/CDC Swift 172 MB Disk (94351-200S/MVME864)
8 m147fuji2613 Fujitsu Pico Bird 3E 135Mb Disk (2613ESA/MVME863)
9 m147fuji2614 Fujitsu Pico Bird 3E 180Mb Disk (2614ESA/MVME864)
10 m147fuji2624 Fujitsu Pico Bird 4 500Mb Disk (2624SA/MVME866)
11 m147fuji2622 Fujitsu Pico Bird 4 300Mb Disk (2622SA/MVME865)
12 m147fuji2652 Fujitsu Super Humming Bird 1.75 Gb Disk (2652SA/MVME878)
13 m147fuji2694 Fujitsu Pico Bird 5 1 Gb Disk (2694SA/MVME867)
14 m147micr1578 MICROPOLIS 300Mb Disk (1578)
15 m147micr1588 MICROPOLIS 600Mb Disk (1588)
16 m147micr1598 MICROPOLIS 1Gb Disk (1598)
17 m147sea3283 Seagate 240 Megabyte Disk (ST3283N)
---> Enter a number, a name, the initial part of a name, or
? or <number>? for HELP, or q to QUIT [m147cdcIV]:
You noted the disk type for your system in step 6. (See Figure 145
for an example.) Most of the disk drives shown in the above figure
are not used by Nortel. Some common disk types used by Nortel
and their corresponding selection numbers are listed in the table
below.
Note:
If your drive is not listed, but another drive of the same size is
listed, use the option number for the listed drive. If you experience
difficulties, contact your Nortel support personnel.
Disk types used
Select this number
CDC ST1126N 9204 (104 Mbyte)
6
CDC ST1201N (172 Mbyte)
7
Fujitsu M2614S (180 Mbyte)
9
Seagate ST3283N (240 Mbyte)
17
Содержание Link/Customer Controlled Routing
Страница 2: ...ii 553 3202 210 Standard October 1998...
Страница 4: ...iv Publication history 553 3202 210 Standard October 1998...
Страница 14: ...xiv Contents 553 3202 210 Standard October 1998...
Страница 56: ...38 Chapter 3 Overview of Customer Controlled Routing 553 3202 210 Standard October 1998...
Страница 132: ......
Страница 168: ...150 Chapter 8 Hardware installation procedures 553 3202 210 Standard October 1998...
Страница 388: ...370 Chapter 13 Meridian Mail configuration 553 3202 210 Standard October 1998...
Страница 496: ...478 Chapter 14 Software installation upgrade and update procedures 553 3202 210 Standard October 1998...
Страница 562: ...544 Chapter 19 Single Terminal Access 553 3202 210 Standard October 1998...
Страница 570: ...552 Chapter 20 Ordering 553 3202 210 Standard October 1998...