McHale
Fusion Vario
Baler & Wrapper
45
5.11 Connecting the control box
The electronic control box must be located inside the tractor cab in the operator’s field
of vision and within easy reach of the red emergency stop button.
. Secure the control unit in the tractor cab, using the V-brackets and
fasteners provided. The male half attaches to the control box and the female half
attaches to the tractor cab allowing for quick placement/removal, every time it is used.
Ensure that the cable to the machine is not under tension and not near sharp edges,
etc. The control box is to be connected to a 12 V, 20 A power supply, using the supplied
euro lead or the battery power cable. The control box is not waterproof, it must be
protected from rain.
5.12 Lighting system
The 7-pin plug of the lighting system on the machine must be connected to the 7-pin
socket on the tractor.
WARNING: Machine must be connected to free flow tank return
The machine must be connected to a free flow tank return at all times
during it’s operation, otherwise damage to the machine components
may occur.
CAUTION: Do not connect the control box to a 24 V power supply
Do not attempt to connect the control box to a power supply greater
than 12 V, as machine component damage will result.
NOTE: Check lighting system before travelling on the road
Before travelling on a public road, the operator must ensure that the
complete (tractor and machine) lighting system is in a fully functioning
condition.