Unblock
This is not really an error message but it signifies that unblock is active. A quick push
on ‘Reset unblock’ (Button R2) on the control box will restore everything to a working
condition.
Lube count
An alarm is provided to remind the operator to grease the
machine and top up the lubrication oil
. This counts down
from 300 and gives a reminder at zero. Press “Reset”
(Button R6) to clear the warning.
It may be reset sooner, if
desired, from within the bale count menu.
(2018)
Knife pressure too high
This tells the operator that the hydraulic pressure holding up
the chopping knives is too high for baling which could lead
to knife or machine damage. This warning will be seen if
manually raising the knives with max pressure.
. Switch back to Manual Mode and lower the
knives to get rid of this warning.
(2003 & 2011)
Low voltage
If the voltage drops below 11 volts, then this warning will be
displayed. The usual causes are nearly always either an
inadequate power lead cable or corroded connections.
Ensure the cable connection to the euro socket is of good
quality. Check the tractor power supply.
(2012)
Stop switch status
This indicates that ‘Stop’ (Button 11) has been activated on
the control unit. This disables all machine functions.
Twist the ‘Stop’ Button clockwise to reset.
(2014)
Unblock
(2001)
Reset unblock
(2002)