STEP 1
Connect the smart tester
Turn the ignition ON
Initialise the diagnostic tool
Record the DTC and clear
Turn ignition OFF
Turn ignition ON
Verify if P0691 is present?
Is P0691 present?
Intermittent problem exists
Refer the intermittent problem
inspection procedure
STEP 2
Ignition OFF
Remove the pressure switch
relay
Check the continuity between
pin 85 of the pressure switch
relay seating and battery ground
Is the continuity
exists?
Examine the short circuit of
pressure switch relay control
signal wire with ground
Replace the wiring harness
Clear the DTC and verify
Suspect EMS ECU malfunction
Replace EMS ECU with a new
one.
Check and verify for any new
DTC’s
NO
YES
YES
NO
P 0691
306