DIAGNOSTIC MANUAL MAN-00201
QUANTO
EMS
SEP 2012/Rev 1
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution
© 2012 Mahindra & Mahindra Ltd.
`
STEP 1
Connect the smart tester
Turn the ignition ON
Initialise the diagnostic tool
Record the DTC and clear
Turn ignition OFF
Turn ignition ON
Verify if P0004 is present?
Is P0004 present?
Intermittent problem exists
Refer the intermittent problem
inspection procedure
STEP 2
Ignition OFF
Fuel metering unit wiring
harness connector (C35)
DISCONNECTED
Check the resistance between
pin 1 and pin 2 of fuel metering
unit wiring harness connector
I
Is the continuity
exists?
Examine the short circuit of fuel
metering unit control wire with
battery positive
Replace the wiring harness
Clear the DTC and verify
Suspect fuel metering unit
internal failure
Replace high pressure fuel
pump with a new one.
Check and verify for any new
DTC’s
NO
YES
YES
NO
P 0004
157