Maintenance / Troubleshooting
Eurosystem / Profi-LON
D1 E101BA1-GB09
5.3
5.3 Side-Slip
Tester
Maintenance work
Interval
Inspect, clean and lubricate the floor assembly.
every 200 hours or annually
Do not readjust or mechanically modify the sensor in any way
1 Remove screws (A) from test plate.
2 Remove test plate to open side-slip tester.
3 Remove any residue from ground pan.
4 Remove roller bearings from slides.
5 Remove spacer rollers from slides.
6 Clean
slides.
7 Clean spacer rollers and roller bearings.
8 Generously lubricate slides with multipurpose grease. Reassemble spacer rollers and roller
bearings in their correct sequence and position.
9 Replace spacer rollers and roller bearings.
10 Check correct position of spacer rollers and roller bearings.
11 Put back test plate.
12 Fasten test plate with 3 screws