Eurosystem / Profi-LON
Profi-LON Operation
3.14
D1 E101BA1-GB09
3.6
Noise Investigation (Optional)
The manual operation of the shock absorber tester is used for noise investigation on wheels or
suspension. The test plates can be switched on for as long as required. No test values are
recorded.
3.6.1
Manual Operation without Remote Control
Selection of the side to be tested must be done before the test stand is occupied.
Once test lane is ready (section 3.2.1) proceed as follows.
1 Prepare noise investigation
Use single wheel switch to select the desired side.
2 Drive onto test plate
→
Test plate on selected side will vibrate until switched off with
single wheel switch.
left
right
Never exit the shock absorber test plates when they are vibrating. This can result in
equipment damage
3 Noise investigation on the other side
Turn single wheel switch to position 0.
→
The drive switches off.
Turn switch to the other side.
→
The drive of the other side switches on.
4 Complete
test
Turn single wheel switch to position 0.
→
The motors switch off. The ON lamp of the analogue display blinks briefly for confirmation
when the shock absorber test plates are exited.
Содержание SA 2 Euro
Страница 19: ...Eurosystem Profi LON Safety 2 4 D1 E101BA1 GB09...
Страница 39: ...Eurosystem Profi LON Profi LON Operation 3 20 D1 E101BA1 GB09...
Страница 119: ...Eurosystem Profi LON Maintenance Troubleshooting 5 8 D1 E101BA1 GB09...
Страница 128: ...Appendix Eurosystem Profi LON D1 E101BA1 GB09 6 9 6 2 Short Instructions...
Страница 129: ...Eurosystem Profi LON Appendix 6 10 D1 E101BA1 GB09...
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......