Appendix
Eurosystem / Profi-LON
D1 E101BA1-GB09
6.3
6.1 System
Variables
No. Description
Default
Unit Comments
51
Speedometer tester: 1st target speed
This variable sets down the first target speed which the
test vehicle's speedometer should approach.
30
km/h
52
Speedometer tester: 2nd target speed
This variable sets down the second target speed which
the test vehicle's speedometer should approach.
60
km/h
53
Speedometer tester: 3rd target speed
This variable sets down the third target speed which the
test vehicle's speedometer should approach.
90
km/h
54
Speedometer tester: 4th target speed
This variable sets down the fourth target speed which
the test vehicle's speedometer should approach.
120
km/h
55
Speedometer tester: 5th target speed
This variable sets down the fifth target speed which the
test vehicle's speedometer should approach.
150
km/h
56
Speedometer tester: 6th target speed
This variable sets down the sixth target speed which the
test vehicle's speedometer should approach.
180
km/h
57
Speedometer tester: 7th target speed
This variable sets down the seventh target speed which
the test vehicle's speedometer should approach.
210
km/h
58
Speedometer tester: 8th target speed
This variable sets down the eighth target speed which
the test vehicle's speedometer should approach.
220
km/h
59
Speedometer tester: 9th target speed
This variable sets down the ninth target speed which the
test vehicle's speedometer should approach.
230
km/h
60
Speedometer tester: 10th target speed
This variable sets down the tenth target speed which the
test vehicle's speedometer should approach.
240
km/h
61
Speedometer tester: max. display
180
km/h
62
Speedometer tester: Speed window
A range within the speed must lie is set dowm in this
variable so that the test value is automatically filed.
5
km/h
63
Speedometer tester: Time window
The time set down in this variable has influence on the
automatic storing of the test values. Only when the
speed is in the speed window, as set down in variable
62, during the time set down here will the test value be
automatically stored.
30
1/10 s
64
not used
--
--
65
LPS-File read-in possible
Only if LPS_IN directory is available
Active only after renewed program start
0
0 = inactive
1 = active
66
Task switching Windows/Eurosystem possible
(Taskswitching)!
Active only after renewed program start!
2
1 = inactive
2 = active
67
Spain / Ireland Mode
0
0 = inactive
1 = active
68
License no. always with capital letters
1
0 = inactive
1 = active
69
Norway –Mode
0
0 = inactive
1 = active
Содержание SA 2 Euro
Страница 19: ...Eurosystem Profi LON Safety 2 4 D1 E101BA1 GB09...
Страница 39: ...Eurosystem Profi LON Profi LON Operation 3 20 D1 E101BA1 GB09...
Страница 119: ...Eurosystem Profi LON Maintenance Troubleshooting 5 8 D1 E101BA1 GB09...
Страница 128: ...Appendix Eurosystem Profi LON D1 E101BA1 GB09 6 9 6 2 Short Instructions...
Страница 129: ...Eurosystem Profi LON Appendix 6 10 D1 E101BA1 GB09...
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......