Table 3-1. GPD 205 Constants - Continued
Setting Range
Setting
Factory
Ref.
Constant
Name
(and units)
Increment
Setting
Page
Maximum frequency (Fmax)
50.0 - 400 (Hz)
0.1
60.0
37
(< 100 Hz);
1
(
≥
100 Hz)
Maximum voltage (Vmax)
1 - 255/510 (V) *
1
230/460 *
Maximum voltage frequency (Fa)
0.6 - 400 (Hz)
0.1
60.0
(< 100 Hz);
Frequency midpoint (Fb)
0.5 - 399 (Hz)
1
1.5
(
≥
100 Hz);
Voltage midpoint (Vc)
1 - 255/510 (V) *
1
12/24 *
Minimum frequency (Fmin)
0.5 - 10.0 (Hz)
0.1
1.5
Minimum voltage (Vmin)
1 - 50/100 (V) *
1
12/24 *
Motor rated current
0.0 - 25.5 (A)
0.1
See
40
Note 1
Electronic thermal motor protection
0 - 4
1
0
40
Stall prevention during deceleration
0, 1
1
0
42
Stall prevention level during
30 - 200 (%)
1
170
42
acceleration
Stall prevention level at set speed
30 - 200 (%)
1
160
43
Momentary power loss function
0 - 2
1
0
43
selection
Carrier frequency
1 - 6
1
4
44
(x 2.5 kHz)
Automatic torque boost gain
0.0 - 3.0
0.1
1.0
44
Frequency command gain
0.10 - 2.00
0.01
1.00
45
Frequency command bias
–99 - 99 (%)
1
0
Frequency command upper limit
0 - 110 (%)
1
100
45
Frequency command lower limit
0 - 110 (%)
1
0
Control circuit terminal FR function
0, 1
1
0
46
Analog monitor selection
0, 1
1
0
46
Analog monitor gain
0.00 - 2.00
0.01
1.00
* Where two values are given (xx/xx) in Setting Range and Factory Setting, the first is
for 115V or 230V drives, and the second is for 460V drives.