Section 3. PROGRAMMING FEATURES
3
3..1
1 G
GE
EN
NE
ER
RA
AL
L..
Paragraphs in this section provide descriptions of the
GPD 205 features which are defined by programmed settings in memory (see Table
3-1). These feature descriptions, based on 2-Wire factory reset, appear in numerical
order by constant number.
3
3..2
2 C
CO
ON
NS
ST
TA
AN
NT
T S
SE
ET
TT
TIIN
NG
G E
ER
RR
RO
OR
RS
S..
The display “ E
E
r
r r
r ” will appear on the
Digital Operator for one second, then the previously set constant value is displayed,
if any of the following conditions exists when the E
EN
NT
TE
ER
R key is pressed while setting
a new value for a constant:
1)
The set values of input terminal function selections 1, 2 and 3 (n
n 0
0 6
6 ,
n
n 0
0 7
7 , and n
n 0
0 8
8 ) are the same.
2)
The following conditions are not satisfied when setting the V/f
pattern:
Max. output freq. ≥ Max. voltage output freq. ≥ Mid. output freq. ≥ Min. output freq.
(n
n 2
2 4
4 )
(n
n 2
2 6
6 )
(n
n 2
2 7
7 )
(n
n 2
2 9
9 )
For details, refer to pages 37-39.
3)
The following conditions are not satisfied when setting prohibited
frequencies:
Prohibited frequency 3 ≥ Prohibited frequency 2 ≥ Prohibited frequency 1
(n
n 5
5 8
8 )
(n
n 5
5 7
7 )
(n
n 5
5 6
6 )
4)
Frequency reference lower limit (n
n 4
4 2
2 ) > Frequency reference upper
limit (n
n 4
4 1
1 ).
5)
Motor rated current (n
n 3
3 1
1 ) > 120% of drive rated current.