My XCi has power problems
WARNING: Before troubleshooting power problems, ensure that you've pressed a
button on the front of the enclosure to "wake-up" the XCi device. The most common
"reason" for a perceived power issue is that the LCD "appears" to be dead.
Symptom
Cause
Remedy
Low/Flat
battery
(consistently <12 V)
Old battery
Replace battery
Weak or no solar charge
Check solar panel undamaged
Check solar panel for dirt and
clean if necessary
Check solar panel is plugged in
Check wiring of solar panel is
correct (polarity)
No external power
Check trickle charger is plugged
in
Check trickle charger is turned
on
Check wiring of trickle charger
is correct (polarity)
Measurement interval too short
Integration period too long
Too many sensors for power
supply
Check the "Power consumption
guide"
None of
the above
XCi must be drawing high cur-
rent
for service
MACE XCi User Manual - 219 -
Содержание HVFlo XCi
Страница 1: ......
Страница 10: ...MACE XCi User Manual 10...
Страница 18: ...MACE XCi User Manual 18...
Страница 21: ...MACE XCi User Manual 21...
Страница 50: ...MACE XCi User Manual 50...
Страница 98: ...MACE XCi User Manual 98...
Страница 173: ...MACE XCi User Manual 173...
Страница 178: ...MACE XCi User Manual 178...
Страница 191: ...NOTE In the example the Net flowrate will be the sum of Flow Rate 1 Flow Rate 2 Flow Rate 3 MACE XCi User Manual 191...
Страница 211: ...For a short video of the procedure click Play MACE XCi User Manual 211...
Страница 233: ...5 Tighten all three screws 6 Reconnect the battery cable assembly to the backplane board MACE XCi User Manual 233...
Страница 238: ...3 Unscrew the locking ring using the tool and remove completely MACE XCi User Manual 238...
Страница 239: ...4 Remove the damaged ceramic depth sensor MACE XCi User Manual 239...
Страница 250: ...MACE XCi User Manual 250...