14. Carefully route the cable from the sensor back to where the XCi device enclosure will be mounted.
WARNING: Particular care should be taken when routing cables to ensure
that moisture CANNOT enter the connector of the sensor cable as permanent
damage may occur
NOTE: MACE recommends that all cables be appropriately routed through
electrical conduit or other similar mechanism. MACE will not be liable for
damage to cables, especially that caused by vehicles, digging implements,
animals or debris in the pipe or channel.