Are there any other acoustic flow meters installed in the same pipe ?
Yes
– Move the Doppler sensor installation point at least 25m away.
No
– The stream flow is suitable for Doppler ultrasonic flow measurement.
Does the proposed site have obstructions in the pipe which might cause irregularities in the flow
(eg. pumps, elbows, constrictions, valves, gates etc)?
Yes
– You will need to install the sensor at a point where there is at least eight pipe diameters of straight pipe
with no obstructions. MACE recommends that the sensor is mounted so that there is a distance of at least six
pipe diameters of straight pipe in front of it and at least two pipe diameters of straight pipe behind it.
No
– Even when there are no obvious obstructions, MACE recommends observing the instructions described
above. In all cases, the sensor should be mounted so that it is as far away from any disturbance as practical.
MACE XCi User Manual - 29 -
Содержание HVFlo XCi
Страница 1: ......
Страница 10: ...MACE XCi User Manual 10...
Страница 18: ...MACE XCi User Manual 18...
Страница 21: ...MACE XCi User Manual 21...
Страница 50: ...MACE XCi User Manual 50...
Страница 98: ...MACE XCi User Manual 98...
Страница 173: ...MACE XCi User Manual 173...
Страница 178: ...MACE XCi User Manual 178...
Страница 191: ...NOTE In the example the Net flowrate will be the sum of Flow Rate 1 Flow Rate 2 Flow Rate 3 MACE XCi User Manual 191...
Страница 211: ...For a short video of the procedure click Play MACE XCi User Manual 211...
Страница 233: ...5 Tighten all three screws 6 Reconnect the battery cable assembly to the backplane board MACE XCi User Manual 233...
Страница 238: ...3 Unscrew the locking ring using the tool and remove completely MACE XCi User Manual 238...
Страница 239: ...4 Remove the damaged ceramic depth sensor MACE XCi User Manual 239...
Страница 250: ...MACE XCi User Manual 250...