Reference Sheets for GRAFIK Eye Dimming Panel
26
Note:
T
he chart at right is for a GRX-4x24, which uses three
addresses. A GRX-4x16 will have two addresses.
GRX-4116/4516 and GRX-4124/4524 Control
Units
The 16 and 24 zone GRAFIK Eye Control Units offer an
expanded number of zones that can be controlled from a single
wall station. The zone intensity LEDs on the GRX-4x16 or GRX-
4x24 will display the light level of eight zones at a time. Other
sets of zones may be displayed and controlled by pressing the
Zone Select Button.
Addressing
The GRX-4x16 and the GRX-4x24 Control Units take multiple,
consecutive addresses. The GRX-4x16 Control Unit takes up two
consecutive addresses, and the GRX-4x24 Control Unit requires
three. To ensure there are sufficient addresses available, any
GRX-4x16 and/or GRX-4x24 Control Units in the system should
be addressed first.
Assigning Zones
When assigning zones use the chart on the right as
a guide to see how zones are displayed on the Circuit Selector.
FADE
OVERRIDE
ZONE
MASTER
S
M
SELECT ZONE
1
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
ZONES
1
9
17
2
10
18
3
11
19
4
12
20
5
13
21
6
14
22
7
15
23
8
16
24
For Information, call
the Lutron Hotline.
(800) 523-9466
http://www.lutron.com
Zone Select Button
GRX-4124 Control Unit
16 and 24 Zone
GRX Control Units
If Control Unit’s
Addresses are . . .
A1, A2, A3
A2, A3, A4
.
.
.
.
.
.
A6, A7, A8
Zones on the Control
Unit . . .
1—8
9—16
17—24
1—8
9—16
17—24
.
.
.
1—8
9—16
17—24
Will appear on the
Circuit Selector . . .
A11—A18
A21—A28
A31—A38
A21—A28
A31—A38
A41—A48
.
.
.
A61—A68
A71—A78
A81—A88