Reference Sheets for GRAFIK Eye Dimming Panel
37
Neon Tube Application
Information
Reference Sheet
25
22
20
18
15
14
13
12
11
10
9
25
22
20
18
15
14
13
12 11 10
9
15000
60
900
77
64
58
54
45
X
X
X
X
X
X
96
80
72
64
58
51
48
44 38 35
X
30
450
77
64
58
54
45
X
X
X
X
X
X
96
80
72
64
58
51
48
44 38 35
X
20
270
X
X
X
X
X
X
X
X
X
X
X
X
X
X
12000
60
720
59
50
46
41
34
32
29
26
X
X
X
76
63
56
50
44
40
37
35 30 28
X
30
360
59
50
46
41
34
32
29
26
X
X
X
76
63
56
50
44
40
37
35 30 28
X
20
225
X
X
X
X
X
X
X
X
X
X
X
X
X
X
9000
120
1080
58
49
41
35
28
25
25
23
20
17
X
74
62
50
42
37
33
30
28 26 22
X
60
540
50
43
36
30
25
23
22
20
18
16
X
64
54
44
36
32
29
26
26 22 20
X
30
270
50
43
36
30
25
23
22
20
X
X
X
64
54
44
36
32
29
26
26 22 20
X
20
180
21
20
18
16
X
X
X
27
25
23
22 18 16
X
7500
120
900
44
35
29
24
22
20
20
17
16
14
X
56
44
36
31
28
26
25
22 20 18
X
60
450
38
31
25
21
20
18
16
16
14
13
X
49
38
31
28
25
22
22
20 18 16
X
30
225
38
31
25
21
20
18
16
16
X
X
X
49
38
31
28
25
22
22
20 18 16
X
20
150
16
16
15
14
X
X
X
22
20
18
17 15 14
X
6000
120
720
35
29
24
20
18
16
16
14
13
11
X
44
37
30
26
22
21
20
18 16 14
X
60
360
30
25
21
17
16
14
14
12
11
10
X
38
32
26
22
19
18
17
15 14 13
X
30
180
30
25
21
17
16
14
14
12
X
X
X
38
32
26
22
19
18
17
15 14 13
X
20
130
14
13
12
10
X
X
X
18
16
14
14 12 10
X
5000
120
600
28
24
20
16
15
14
13
10
9
8
X
37
30
25
21
18
18
15
14 12 10
X
60
300
25
21
17
14
13
12
11
9
8
8
X
32
26
22
18
16
15
13
13 10 10
X
30
160
25
21
17
14
13
12
11
9
X
X
X
32
26
22
18
16
15
13
13 10 10
X
20
100
11
10
10
8
X
X
X
14
13
12
11
9
8
X
4000
60
240
20
17
14
12
10
9
8
8
7
6
X
26
22
18
15
14
13
12
11
9
8
X
30
140
20
17
14
12
10
9
8
8
X
X
X
26
22
18
15
14
13
12
11
9
8
X
20
90
8
8
8
7
X
X
X
11
10
10
10
7
6
X
3000
60
180
13
10
9
8
8
7
7
6
5
5
X
18
14
13
11
10
9
8
7
6
6
X
30
100
13
10
9
8
8
7
7
6
5
5
X
18
14
13
11
10
9
8
7
6
6
X
20
75
6
6
5
5
4
3
X
8
7
6
6
5
4
X
2000
30
75
5
5
5
5
X
X
X
7
6
6
6
5
4
X
20
50
5
4
4
4
X
X
X
6
6
6
5
4
3
X
Recommended gas pressure, mm/Hg
6
7 7.5
8
9
10
10
11
12
13
6
7 7.5
8
9
10
10
11 12 13
Luminous Tube Length Chart for Neon/Cold-Cathode Dimming Applications
Notes:
■
X denotes this combination cannot be successfully dimmed.
■
Tube length is shown in feet. To convert to meters, 1ft. = 0.305 m.
■
If using a center-tap on a center-tapped transformer, the
secondary voltage will be reduced by half.
Warning!
This chart has been calculated for dimming
purposes and must not be used for non-dimming
installations.
Danger!
Potentially hazardous high voltage can be
present. Testing, handling, and servicing should be done
only by qualified personnel.
TRANSFORMER
Total Lamp Length = (8 Lamps X 4 ft) + (8 Lamps X 1 ft for each pair of electrodes) = 40 ft.
A 12000V, 60mA, 720VA transformer should be used (Capable of dimming 41 ft.)
* Each pair of electrodes equals one foot of tube. Example application = 8 red neon, 4 foot long, 18 mm dia., 60 mA lamps
Transformer Ratings
Approximate Number of Feet of Tubing and Pairs of electrodes*
Secondary
Voltage (V)
Secondary
Short Circuit
Current (mA)
Input Volt-
Amperes with
Secondary Short
Circuit (VA)
Neon Fill (clear or fluorescent red)
Argon/Mercury Fill (colors other than neon red)
Tube Size (millimeters)
Tube Size (millimeters)