Chapter 5 Site-Specific Configuration
Collecting Bulk Statistics
Collecting Bulk Statistics
Overview of Tasks
To collect bulk statistics on ATM and frame relay interfaces on the PSAX sys-
tem to be sent to a remote statistics server, you need to perform the following
tasks:
1. Enable the Bulk Statistics feature on the Feature Turn ON/OFF window.
See “Enabling and Disabling PSAX System Features” on page 5-42.
2. Set up the PSAX system for sending collected statistics to a remote statis-
tics server, such as the NavisXtend Statistics Server (offered by Lucent
Technologies). See the following section for instructions.
3. Select the value Enabled in the Bulk Stats Flag field on the ATM UNI,
the ATM IISP, or the frame relay interface configuration window for an
interface on which you want to collect bulk statistics. For instructions on
interface configuration, see the appropriate PacketStar PSAX I/O module
user guide.
4. Select the value Enabled in the Bulk Stats Flag field on the ATM or
frame relay connection configuration window for a connection on which
you want to collect bulk statistics. For instructions on ATM or frame relay
connection configuration, see the PacketStar PSAX Connections Provisioning
Guide. Note that you must have already set the Bulk Stats Flag field to
Enabled on an ATM or frame relay interface before you configure a con-
nection associated with that interface.
Configuring the PSAX System to Use a Statistics Server
Perform the steps in the following procedure to configure the PSAX system to
use a remote statistics server such as the NavixXtend Statistics Server. The
PSAX system sends collected statistics periodically at a user-specified fre-
quency.
Begin
1
On the Console Interface Main Menu window, select the Site-Specific
Configuration option.
The Site-Specific Menu window is displayed.
2
On the Site-Specific Menu window, select the Bulk Statistics Configura-
tion option.
The Bulk Statistics Configuration window is displayed (see Figure 5-31).
3
Enter values in the fields on this window according to the information
provided in Table 5-36. The commands on this window are described in
Table 5-35.
End