PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Chapter 5 Site-Specific Configuration
Configuring the System for Your Site
Configuring the PSAX System as a TCP Server or a TCP Client
The Connection Gateway API is a protocol that you can use in addition to
SNMP to manage multiple PSAX systems. CGAPI provides an interface to the
PSAX system so that an external workstation, which is acting as a gateway,
can control ATM switching with non-native ATM networking protocols.
Using the API, the gateway and the PSAX system can perform the interwork-
ing for ATM, integrated services digital network (ISDN), signaling system 7
(SS7), channel associated signaling (CAS), and additional protocols.
To configure the PSAX 2300 system as a TCP client or server, perform the fol-
lowing procedure.
Begin
1
In the Site-Specific Configuration window, select the Configure TCP
Server command.
The TCP Server Configuration window is displayed (see Figure 5-10 for
client device setup, and Figure 5-11 for server device setup).
2
Enter values in the fields on this window according to the information
provided in Table 5-16.
3
Select the Apply TCP Server Configuration command.
Time from UTC
Default: -00 : 00
Range: N/A
Format: numeric
Specifies the differential between the local time
and the UTC (GMT) time. Press Enter to cycle
through the predefined set of values to select a
value (either negative or positive) that indicate
the hours and minutes your local time differs
from the UTC time.
Note:
Select 30 for the second segment of this
field if your local time zone is 30 minutes offset
from the UTC.
[Local Time]
Default: current
time
Range: N/A
Format: numeric
(12-hour format
[HH:MM:SS] am or
pm)
Displays the local time of the PSAX system in
12-hour format with the am or pm indicator.
Note:
[Temperature] Default:
N/A
Range: N/A
Format: numeric
(degrees Celsius)
Displays the ambient temperature where the
PSAX system is located.
Table 5-14. Field Descriptions for the System Date and Time Panel on the Site-Specific