Chapter 8 Configuring V5.2 European IDLC
Setting Call Control Resource Allocation Values
8-14
255-700-447
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
spvcAtmPtToPtCalls Default: 002000
Range: 0–10000
Format: Numeric
Specifies the maximum number of SPVC ATM point-
to-point calls to be supported by the PSAX system. Set
the values in the SPVC point-to-point call fields
(spvcCePtToPtCalls, spvcTePtToPtCalls, spvcAtmPtToPt-
Calls, and spvcFrPtToPtCalls) so that the sum of their
values does not exceed the maximum number of
duplex calls per node for SPVCs as indicated in the
table entitled “PSAX System Performance Capabilities
Per Node.”
SPVC Priority Configurations:
If you select the value
Enabled in the spvcGlobalPriorityScheme field, the
total number of calls specified in all of the SPVC call
fields and the number of ATM trunk VCCs cannot
exceed 32 calls.
H.248 Applications:
Set the value in this field to 0.
spvcFrPtToPtCalls
Default: 000900
Range: 0–10000
Format: Numeric
Specifies the maximum number of SPVC frame relay
point-to-point calls to be supported by the PSAX sys-
tem. Set the values in the SPVC point-to-point call
fields (spvcCePtToPtCalls, spvcTePtToPtCalls, spvcAt-
mPtToPtCalls, and spvcFrPtToPtCalls) so that the sum
of their values does not exceed the maximum number
of duplex calls per node for SPVCs as indicated in the
table entitled “PSAX System Performance Capabilities
Per Node.”
SPVC Priority Configurations:
If you select the value
Enabled in the spvcGlobalPriorityScheme field, the
total number of calls specified in all of the SPVC call
fields and the number of ATM trunk VCCs cannot
exceed 32 calls.
H.248 Applications:
Set the value in this field to 0.
spvcPtToMultiPt-
Calls
Default: 000500
Range: 0–500
Format: Numeric
Specifies the maximum number of SPVC point-to-mul-
tipoint calls to be supported by the PSAX system.
SPVC Priority Configurations:
If you select the value
Enabled in the spvcGlobalPriorityScheme field, the
total number of calls specified in all of the SPVC call
fields and the number of ATM trunk VCCs cannot
exceed 32 calls.
H.248 Applications:
Set the value in this field to 0.
spvcPtToMultiPt-
Parties
Default: 001000
Range: 0–4000
Format: Numeric
Specifies the maximum number of parties on SPVC
point-to-multipoint calls to be supported by the PSAX
system.
SPVC Priority Configurations:
If you select the value
Enabled in the spvcGlobalPriorityScheme field, the
total number of calls specified in all of the SPVC call
fields and the number of ATM trunk VCCs cannot
exceed 32 calls.
H.248 Applications:
Set the value in this field to 0.
Table 8-6. Field Descriptions for the Call Control Resource Allocation Configuration Window (Continued)
Field Name
Field Values
Description