Chapter 6 Configuring ATM PNNI
Configuring an ATM PNNI Node Timer
6-14
255-700-447
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
The commands on this window perform the following functions:
Figure 6-6. PNNI Node Timer Configuration Window
Table 6-9. Commands for the PNNI Node Timer Configuration Window
Command
Function
Apply Configuration
Applies the values you set on this window.
Go Back to Previous Screen
Redisplays the PNNI Node Configuration window.
Table 6-10. Field Descriptions for the PNNI Node Timer Configuration Window
Field Name
Field Values
Description
Node Timer Information Panel
[Node Index]
Default: 00000
Range: 1–400
Format: numeric
Displays the node index that identifies a logical
PNNI entity in the PSAX system.
Ptse Holddown..
(100 msec)
Default: 00010
Range: 1–65535
Format: numeric
multiplier of
100 msec
Indicates a PNNI Topology State Element (PTSE),
a collection of PNNI information that is flooded
among all logical nodes in a peer group. The
hold-down timer prevents a node from sending
hello packets at unacceptably high rates. The ini-
tial value of this timer is used by a node to limit
the rate at which it can re-originate PTSEs.
Note:
Each increment entered in this field is a
multiplier of 100 msec. A value of 10 = 1 second,
or 100 msec
×
10.