![Lucent Technologies PacketStar PSAX 2300 Скачать руководство пользователя страница 350](http://html.mh-extra.com/html/lucent-technologies/packetstar-psax-2300/packetstar-psax-2300_user-manual_1946189350.webp)
Chapter 8 Configuring V5.2 European IDLC
Setting Call Control Resource Allocation Values
8-12
255-700-447
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Configuration Guidelines
Table 8-6. Field Descriptions for the Call Control Resource Allocation Configuration Window
Field Name
Field Values
Description
Important:
The ranges of values for numeric fields are software imposed. When changing the val-
ues in these fields, keep in mind that the PSAX system calculates the percentage of the memory
allocation usage from the combination of values you have entered in the fields. This calculation is
displayed in the callContrlResAllocUsage field. When all the values of SVC calls and parties, SPVC
calls, Connection Gateway API endpoints, and Connection Gateway API calls and parties are calcu-
lated as a percentage of memory allocation, this percentage value cannot exceed 100 percent of the
memory allocation. If you enter a combination of values that exceeds 100 percent when calculated
by the system, the following error message is displayed:
T-CallControlResAllocFail
. If you
receive this error message, adjust the values in the fields and use the Apply Configuration com-
mand to recalculate the allocation usage percentage value. When you enter a combination of values
that correctly results in a value of 100 percent or less, the following informational message is dis-
played:
Resource allocation configuration has been applied. Need to save configura-
tion and reboot the system to take effect.
svcPtToPtCalls
Default: 002000
Range: 0–15000
Format: Numeric
Specifies the maximum number of SVC point-to-point
calls to be supported by the PSAX system.
H.248 Applications:
For AAL2, this field must be
greater than or equal to the sum of the values in the
atmTrunkNarrowBandCalls and atmTrunkVccs fields.
Set this field to the same value as the
sgApiPtToPtSvcCalls field. For example, if the Maxi-
mum Number of Contexts field on the H.248 Transport
and Resource window is set to 4000 and the Maximum
Number of Terminations field on that window is set to
8000, then the recommended values for this field are
4000 for AAL1 and 4100 for AAL2.
svcPtToMultiPtCalls Default: 002000
Range: 0–4000
Format: Numeric
Specifies the maximum number of SVC point-to-mul-
tipoint calls to be supported by the PSAX system.
H.248 Applications:
Set the value in this field to 0.
svcPtToMultiPtPar-
ties
Default: 002000
Range: 0–4000
Format: Numeric
Specifies the maximum number of parties on SVC
point-to-multipoint calls to be supported by the PSAX
system. Set the value in this field to be greater than or
equal to the value in the svcPtToMultiPtCalls field,
because each point-to-multipoint call must have at
least one party.
H.248 Applications:
Set the value in this field to 0.
Содержание PacketStar PSAX 2300