255-700-447
5-85
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Chapter 5 Site-Specific Configuration
Saving the Equipment Configuration Values and Logging Off
2
Select the Save Configuration command or press Ctrl+A.
Wait a few seconds while the system writes the values to the PSAX sys-
tem database. The system displays the following message while it is exe-
cuting this command:
Saving the equipment and connection information
Note:
In PSAX systems with redundant CPUn modules, the standby
CPUn module reboots every time you save the configuration on
the primary CPUn module. This event is a function of the SVC
retention feature and the result of saving the configuration
changes you have made.
When the save configuration function is completed, the system displays
an appropriate message as described in Table 5-42.
Figure 5-36. Save Configuration [Modified] (Before Saving)
Table 5-42. Messages Generated after the Save Configuration Process
When a PSAX
system is...
the system displays...
nonredundant
T-SaveConfiguration: saveConfigurationReasonCode=All-OK
redundant
T-SaveConfiguration: saveConfigurationReasonCode =
Expect2ndCPUCardFailedOrRemoved
*
The standby CPUn module is rebooted when the save command is issued.
After the standby CPUn module reboots, the system displays the following
message:
T-SaveConfiguration: saveConfigurationReason-
Code=FileTransferCompleted
*
This message indicates that while the standby CPUn module reboots after you select the
Save
Configuration
command, the standby CPUn module is temporarily unavailable.