255-700-447
8-31
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Chapter 8 Configuring V5.2 European IDLC
Setting Call Control Resource Allocation Values
Align Ports Method Default: V5SecondE
ditionPortAlign
Range: N/A
Format: Predefined
alphanumeric
Indicates type of flag used for port alignment
method to use along with interface type.
V5PortAlignUndefi
ned
Port align protocol not defined.
V5PortIndividualP
ortAlign
Informs the V5 stack to unblock all relevant PSTN
and ISDN ports one by one.
V5FirstEditionPort
Align
Informs the V5 stack to unblock all relevant PSTN
and ISDN ports as a single entity.
V5SecondEditionP
ortAlign
Informs V5 stack to unblock or block all relevant
PSTN and ISDN ports as a separate entity.
AN Initiate Link
Proc
Default: False
Range: N/A
Format: Predefined
This flag indicates whether the Access Network or
Local Exchange initiates the Link Id procedure. If
true, the AN should initiate it. If False, the LE
should initiate it.
False
False informs the V5 stack not to initiate the link
identification procedure.
True
True informs V5 stack to initiate the link dentifi-
cation procedure.
[L1 Fsm Normal
Timer]
Default: 500
Range: 1–1000
Format: msec
Specifies the L1 finite state machine normal
timer, that the E1 facility uses to enter into the
NORMAL operational state. Values are given in
milliseconds.
[L1 Fsm LosOrLos
Timer]
Default: 2500
Range: 1–2500
Format: msec
Specifies the L1 finite state machine loss of signal
or loss of frame timer for the E1 facility to enter
into the non-operational state when LOS/LOF is
set. Values are given in milliseconds.
[L1 Fsm Ais Timer] Default: 2500
Range: 1–2500
Format: msec
Specifies the L1 finite state machine alarm indica-
tor signal timer that the E1 facility uses to enter
into the non-operational state when there is an
alarm indication. Values are given in millisec-
onds.
[L1 Fsm Rai Timer] Default: 2500
Range: 1–2500
Format: msec
Specifies the L1 finite state machine RAI signal
timer for the E1 facility to enter into the non-
operational state when an RAI occurs. Values are
given in milliseconds.
Resource Manager
TR1
Default: 500
Range: 500–1500
Format: msec
Specifies the timer used by resource manager to
send BCC:ALLOCATION REJECT message if it
does not receive a V5ConnectComplete message
within this time. Values are given in milliseconds.
Table 8-18. Field Descriptions for the V5 Interface Variant Configuration Window (Continued)
Field Name
Field Value
Field Description