Chapter 13 Upgrading PSAX System Software
Manually Selecting I/O and Server Module Firmware Drivers
13-28
255-700-447
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Status Default:
N/A
Range: N/A
Format: Predefined
alphanumeric
Displays the status of the firmware downloading
after you select the Start Upgrade command. A
system message is also displayed in the status line
at the bottom of the window.
Note:
If you have just upgraded your PSAX sys-
tem software, make sure that the value Done is
displayed in this field for all modules before you
do any of the following:
•
Reboot the primary or standby CPUn module
or the PSAX chassis
•
Perform a primary CPU switchover
•
Synchronize the standby CPUn module soft-
ware version with the primary CPUn module
•
Restore your database files from a separate
storage medium to the PSAX system using the
Remote Database Operation window
•
Change any configuration values
Done
Indicates that the firmware downloading on the
module was complete and successful.
Progress
Indicates that the new firmware is currently
being downloaded.
Retry
Indicates that the PSAX system is attempting to
download the firmware. After 2,048 attempts are
tried unsuccessfully, the value Failed is displayed
in this field.
ReqRepTimeout
Indicates that a request to download the firm-
ware was made but no reply from the module
was received during the designated time period.
RequestPending
Indicates that a request to download the firm-
ware was made and the system is waiting for a
response from the module.
Failed
Indicates that the attempt to download the new
firmware failed.
RemoveCardBefore
Finish
Indicates that while the firmware was being
downloaded to the module, the user removed it
from the PSAX chassis; therefore, the firmware
download was not completed.
WrongCardType
Indicates that one type of module was configured
in this slot in the chassis, but now a different
module occupies this slot.
WrongCardSType
Indicates that one type of stratum module was
configured in this slot in the chassis, but now a
different stratum module occupies this slot.
Table 13-14. Field Descriptions for the Firmware Version Control Window (Continued)
Field Name
Field Values
Description