255-700-447
7-13
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Chapter 7 Configuring ATM Trunking
Adding a Bearer VCC Identifier
Adding a Bearer VCC Identifier
Begin
1
On the ATM Trunking Remote IWF Configuration window, select the Go
to Bearer VCC Table command.
[Oper Status]
Default: Idle
Range: N/A
Format: Predefined
alphanumeric
Displays the operational status of the local IWF.
Idle
Indicates that the connection is not operational.
OutOfService
Indicates that the PVC connection is not
operational.
Init
Indicates that the connection is being initiated.
Connecting
Indicates that the connection is being connected
but layer 2 is not yet operational.
Active
Indicates that the connection is operational and is
transmitting traffic.
Release
Indicates that the connection is being released.
Retry Timer
Default: 30
Range: N/A
Format: Seconds
Indicates the time in seconds that the PSAX sys-
tem will wait before attempting to establish the
ATM Trunking Signalling VCC SPVC connection
after a previous failed call attempt. A value of 0
indicates that retries will be attempted immedi-
ately.
Retry Limit
Default: 0
Range: N/A
Format: Numeric
Indicates the number of times that the PSAX sys-
tem attempting to establish the ATM Trunking
Signalling VCC SPVC connection. A value of 0
indicates an unlimited number of attempts.
Restart
Default: Restart
Range: N/A
Format: Predefined
Indicates whether the active SVC connection is
released, if necessary, and a new connection
setup procedure takes place.
Restart
Indicates that the PSAX system will restart the
SPVC connection.
Noop
Indicates that the PSAX system will not restart
the SPVC connection.
Retry Counter
Default: 0
Range: N/A
Format: Numeric
Indicates the number of failed attempts to estab-
lish the connection. This field resets to 0 when-
ever a connection is successfully established or
the ATM Trunking Signalling VCC SPVC connec-
tion is restarted.
Table 7-10. Field Descriptions for the ATM Trunking Sig VCC Configuration Window (Continued)
Field Name
Field Values
Description
Содержание PacketStar PSAX 2300
Страница 679: ......
Страница 680: ...Part Number 2300M0A9001A1 Copyright 2003 Lucent Technologies All rights reserved ...