Table 5-13. Field Descriptions for the System Identification Panel on the Site-Specific
Configuration Window
Field Name
Field Values
Description
[Chassis Type]
Default: N/A
Range: N/A
Format: predefined
alphanumeric
Displays the type of PSAX system you are config-
uring.
Mux Tcp Type
Default: Client
Range: N/A
Format: predefined
alphanumeric
Specifies how the PSAX system is defined for the
TCP connection between the PSAX system and
the connection gateway for messages transmitted
through the Connection Gateway API. If the
PSAX system is designated as the client device,
the PSAX system establishes the connection to
the connection gateway. If the PSAX system is
designated as the server device, the connection
gateway establishes the connection to the PSAX
system.
Client
Indicates that the PSAX system is serving as the
client device.
Server
Indicates that the PSAX system is serving as the
server device.
Site Name
Default: N/A
Range: 1–19
Format: predefined
alphanumeric
Specifies the site name that you define for this
PSAX system. Enter a site name having no more
than 19 characters of the following types: alpha-
numeric,
-
(hyphen), and
_
(underscore). Do not
use spaces or periods.
Switch IP Addr
Default: 000.000.000.0
00
Range: N/A
Format: valid dotted
quad
Specifies the IP address that identifies the PSAX
system. This field is only required to be set if you
have a redundant PSAX system. Determine from
your network configuration plan the IP address
you want to use.
IP Mask (display
only)
Default: 000.000.000.0
00
Range: N/A
Format: valid dotted
quad
Specifies the IP mask for Ethernet access to your
PSAX system. This field determines which part of
the IP address is the network identifier, and
shows the subnet mask of the network.
Gateway Addr
Default: 000.000.000.0
00
Range: N/A
Format: valid dotted
quad
Specifies the Ethernet address of the router,
which will act as a gateway that the PSAX system
will use to access other networks. Leave this field
blank if you are not using a router. This address
cannot be the same as the CPU IP and switch IP
addresses.
CPU IP Addr
Default: 000.000.000.0
00
Range: N/A
Format: valid dotted
quad
Specifies the IP address of the active CPU module
for the PSAX system. Determine from your net-
work configuration plan the IP address you want
to use.