Chapter 5 Site-Specific Configuration
Rebooting CPUn Modules in Redundant and Nonredundant Systems
5-48
255-700-447
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Begin
Note:
Performing this procedure does NOT interrupt traffic running
through the PSAX chassis.
1
On the Console Interface Main Menu window, select the Diagnostics
option.
The Diagnostics Menu window is displayed.
2
On the Diagnostics Menu window, select the Reboot Hardware Compo-
nents option.
The Remote Reboot Configuration window (see Figure 5-19) is dis-
played.
3
Select the Primary Switchover command.
The following message is displayed in the status line:
Are you sure that you want to do the primary switchover?
(y/n)
4
Press the Y key.
The PSAX system switches processing control from the primary CPUn
module to the backup (standby) CPUn module, and immediately begins
rebooting the original primary CPUn module. As this process proceeds,
the new primary CPUn module (originally the standby CPUn) synchro-
nizes the management information base (MIB) data with the new
standby CPUn module (originally the primary CPUn). The green LED
ACTIVE
is illuminated on the primary CPUn module.
End
Figure 5-19. Remote Reboot Configuration Window (Primary Switchover Option
Selected)