255-700-025
C-11
PacketStar
™
Access Concentrator 60 User Guide
, Issue 1
Release 6.3.0
Appendix C Configuring In-Band Management
Using the Hybrid Connection Configuration
Perform the steps in the following procedure to configure a hybrid
connection.
Begin
Steps to Setting Connections for Hybrid Connection Configuration
1
In the hybrid connection type, Ethernet to in-band network routing as
well as ATM channel tunneling is used. Log in as root on the SUN
machine and add a routing table entry using “route add” command:
route add net
< In-Band network address> <PSAX IP address on Ethernet>
<metric>
where the in-band network address = 20.0.0.0
PSAX IP address on Ethernet = {Check Site Specific Configuration -> Site
Specific Configuration -> IP AddrPSAX systemess on the main router PSAX
system [ node A]}
metric = 10
2
In this configuration, only one PSAX system can act as the router to
channel traffic from Ethernet to the in-band network. This is the main
router PSAX system. The main router PSAX system has direct ATM
connections to all remote PSAX systems. (These connections may be
tunneled through a number of switches.)
3
On the main router PSAX system, the in-band management interface
(primary) should be assigned an IP address that is on a different network
than that of its Ethernet interface.
Figure C-3. Hybrid Connection Configuration
PSAX
ATM PVC
Connections
ATM PVC Connections
Node A
Main Router
Ethernet
Connections
Node B
Remote PSAX
NMS
Node C
Node E
Node D
NMS
NMS
Physical Connections via Ethernet LAN
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
PSAX
Содержание PacketStar AC 60
Страница 38: ...Chapter 1 Getting Started 1 14 255 700 025 PacketStar Access Concentrator 60 User Guide Issue 1 Release 6 3 0 ...
Страница 128: ...Chapter 3 System Features 3 80 255 700 025 PacketStar Access Concentrator 60 User Guide Issue 1 Release 6 3 0 ...
Страница 404: ......
Страница 406: ......
Страница 408: ......
Страница 409: ......