Chapter 4 Configuring the Basic System
Configuring the System for Your Site
4-12
255-700-025
PacketStar
™
Access Concentrator 60 User Guide
, Issue 1
Release 6.3.0
3. CPU IP and switch IP addresses cannot be on the same subnet as the
in-band IP address.
4. CPU IP, switch IP, and in-band IP addresses may each be zero, but CPU IP
and Switch IP addresses cannot both be zero (see Number 2 above).
Note:
If the CPU IP address is zero and the
ssid
file on the CPU module
is corrupted, the system cannot access the Ethernet.
5. If non-zero, then the CPU IP, switch IP, and in-band IP addresses have to
be valid IP addresses.
6. If the switch IP address is not zero, then the system will respond to the
Switch IP address; otherwise, the system will respond to the CPU IP
address on the Ethernet port.
7. In a redundant system, both CPU modules must have a unique CPU IP
address; they will have the same switch IP address and in-band IP
address if either address is defined.
Rules for Configuring IP Address Masks
Use the following rules when configuring the CPU IP address and switch IP
address on the Site-Specific Configuration window:
1. The CPU IP address and switch IP address share the same IP mask.
2. The CPU IP address (or switch IP address) and in-band IP address masks
are independent of each other, as long as the CPU IP address (or switch
IP address) and in-band IP address are in different networks.
3. If the CPU IP address (or switch IP address) and in-band IP address are in
the same network, then their masks must be the same.
4. The CPU IP address (or switch IP address) and the in-band IP address are
in the same subnet if the CPU IP address mask (or switch IP address
mask) is the same as the in-band IP address,
and
if the CPU IP address
(or switch IP address) masked out result is the same as the in-band IP
address masked-out result.
5. The CPU IP address and switch IP address must always be on a different
subnet from the in-band IP address (see Number 3 of the previous
section).
Configuring System Identification
ATM Addresses and
OAM Properties
The Master ATM Address and OAM related data panel allows you to enter
and display information about the Master ATM address, the loopback, and
OAM debouncing period.
Entering and
Displaying ATM
Addresses and OAM
Properties
Perform the steps in the following procedure to configure the loopback
parameters on modules that support loopback configuration.