Chapter 4 Loader and Basic Operation
4-11
4.8 How to set Roll-back prevention by Load Cell
4.8.1 Preparations before setting
1)
Input load detect signal such as Load cell at AI1-5G terminal 0~10V inputs come out.
2)
During self-operation of inverter or other inverter, please check whether detect signal
operates well or not.
3)
When detecting wrong operation, please make it right by executing noise shielding or other
management
Keypad display
Descriptions
Set torque bias of CON_32 as ‘Analog’
Set torque balance of CON_35 as ‘0.0%’
Set I/O_07 as ‘Analog Hold’
Set I/O_11 as ‘Torque Bias’
Set I/O_12 as ‘-10~10V’
Set I/O_15 as much as 50ms
Set I/O_43 as ‘Run’
CON
▶
Trq Bias Src
32 Analog
-100.0rpm
SPD
Tq % A
CON
▶
Trq Balance
35 0.0 %
I/O
▶
Ai1 Source
12 -10 ~ 10V
I/O
▶
Ai1 LPF
15 50ms
I/O
▶
Ai1 Define
11 Torque Bias
I/O
▶
P7 define
07 Analog Hold
I/O
▶
OC1 define
43 Run