1  Function of the ETATRACK active Controller 

 

The tracker controller calculates the duration 
of the days based on the output voltages of 
the solar-modules – disconnecting the solar-
array will result in wrong daytime calcula-
tions! 

Parallel operation of tracker control-

ler with battery charger or Inverter can 
cause wrong tracking movements.

 An 

additional small PV-Module should be used 
for such applications: Min. 5 Wp for locations 
between 45°North and 45° South, min. 10Wp 
for locations 

 45°North or South for the 

tracker power supply. Only the total electrical 
separation between tracker controller and 
battery charger / inverter ensures perfect 
operation. 

LORENTZ PS Pump Controllers 

do not require the additional PV-Modul 

 

First connect the motor power cable and the motor reed 
switch, then connect battery and the solar module to the 
controller terminals. The solar module is used for Day / 
Night-detection. 
Set the jumper to northern or southern hemisphere. 
Now the motor can be moved manually in small steps by 
pushing the East or the West button 
Press the Manual button to initialize the controller. 
After that the controller will start the tracking automatical-
ly. 
 
First it will move some degrees to West direction (not with 
the jumper setting to “Southern Hemisphere” as the frame 
is already in West position). Then it will move (back) into 
East direction. 
After reaching the final East position it will start to move 
to the final West position and then back to »High Noon« 
position. That is a learning process for the controller. The 
rest of the first day will be handled as a standard day. 
 

 

In case reverse action is determined the two 
motor cables has to be reversed! 
Disconnect and reconnect the battery and the 
solar module in order to make a controller 
reset and the learning process will start 
again.  

During the night the tracker moves into »High Noon« 
position. After the first night the tracking will fit the real 
duration of the next day. 

Overload protection: 

The tracker controller has an integrated overload protec-
tion: After an overload occurred the controller stops the 
motor, the Overload LED goes On (Power LED goes Off) 
Only disconnecting power can reset the overload ( battery 
and solar). Before resetting please check the mechanical 
conditions: Try to find out where the tracking frame or the 
motor is blocked and check the whole assembly for 
smooth movement. 
 

Polarity protection solar input: 

In case of wrong polarity connection of the solar modules 
to the tracker electronics, no damage will occur. 
Correct the wiring 
 

Polarity protection battery input: 

In case of wrong polarity connection of the battery, the 
fuse will blow.  
Correct the wiring and replace the fuse.  

Power consumption: 

Max. 1,25 kWh per year 

Trouble shooting: 

Check all cables and the fuse first. 
In case of a low battery voltage (11V) the controller shuts 
the system off and moves the tracker to high noon posi-
tion. It can be still moved manually with the east and 
West buttons. 
Once the voltage of the battery has reached 12,5V the 
tracker will start again to follow the sun.  
Check if the tracker can move easily. Disconnect the 
motor if needed and control by hand the easy movement.  